Objective: The hemodynamic effect and early and late survival impact of prosthesis-patient mismatch (PPM) after mitral valve replacement remains insufficiently explored.

Methods: Pubmed, Embase, Web of Science, and Cochrane Library databases were searched for English language original publications. The search yielded 791 potentially relevant studies. The final review and analysis included 19 studies compromising 11,675 patients.

Results: Prosthetic effective orifice area was calculated with the continuity equation method in 7 (37%), pressure half-time method in 2 (10%), and partially or fully obtained from referenced values in 10 (53%) studies. Risk factors for PPM included gender (male), diabetes mellitus, chronic renal disease, and the use of bioprostheses. When pooling unadjusted data, PPM was associated with higher perioperative (odds ratio [OR]: 1.66; 95% confidence interval [CI]: 1.32-2.10; p < .001) and late mortality (hazard ratio [HR]: 1.46; 95% CI: 1.21-1.77; p < .001). Moreover, PPM was associated with higher late mortality when Cox proportional-hazards regression (HR: 1.97; 95% CI: 1.57-2.47; p < .001) and propensity score (HR: 1.99; 95% CI: 1.34-2.95; p < .001) adjusted data were pooled. Contrarily, moderate (HR: 1.01; 95% CI: 0.84-1.22; p = .88) or severe (HR: 1.19; 95% CI: 0.89-1.58; p = .24) PPM were not related to higher late mortality when adjusted data were pooled individually. PPM was associated with higher systolic pulmonary pressures (mean difference: 7.88 mmHg; 95% CI: 4.72-11.05; p < .001) and less pulmonary hypertension regression (OR: 5.78; 95% CI: 3.33-10.05; p < .001) late after surgery.

Conclusions: Mitral valve PPM is associated with higher postoperative pulmonary artery pressure and might impair perioperative and overall survival. The relation should be further assessed in properly designed studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7756724PMC
http://dx.doi.org/10.1111/jocs.15108DOI Listing

Publication Analysis

Top Keywords

prosthesis-patient mismatch
8
mitral valve
8
valve replacement
8
mismatch mitral
4
replacement pooled
4
pooled meta-analysis
4
meta-analysis kaplan-meier-derived
4
kaplan-meier-derived individual
4
individual patient
4
patient data
4

Similar Publications

Background: Lifetime treatment of aortic valve disease is a matter of increasing debate. Although the risks of a second aortic valve intervention are recognized, little attention has been given to the challenges of a third.

Objectives: This study delves into the clinical characteristics, indications, and outcomes of patients undergoing 3 aortic valve interventions.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Transcatheter Aortic Valve-in-Valve Implantation with Newer Generation Evolut Valve by Size of Failed Bioprosthesis.

Anatol J Cardiol

January 2025

Department of Cardiothoracic Surgery Research, Lankenau Institute for Medical Research, Wynnewood, Pennsylvania, USA ; Department of Cardiothoracic Surgery, Lankenau Heart Institute, Main Line Health Wynnewood, Pennsylvania, USA.

Background: To evaluate the clinical outcomes of valve-in-valve transcatheter aortic valve replacement (ViV TAVR) with newer-generation self-expanding Evolut valves according to the size of the failed surgical bioprosthesis.

Methods: This single-center retrospective study evaluated consecutive patients undergoing ViV TAVR with the Evolut Pro/Pro+/Fx between 2018 and 2022. These patients were compared based on the true internal diameter (ID) of the failed bioprosthesis, specifically ≤19 mm (small group) vs.

View Article and Find Full Text PDF

Background: The short-term and midterm impact of gender differences on transcatheter aortic valve implantation (TAVI) has been studied. However, the impact on long-term clinical outcomes remains unclear. The objective of the study was to investigate the impact of gender differences after TAVI on long-term clinical outcomes and structural valve deterioration (SVD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!