Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The length of Descemet's membrane and donor graft sizes in deep anterior lamellar keratoplasty do not match in very steep corneas, which can lead to Descemet's membrane folds. The aim of this study is to establish a theoretical model for graft size calculations for deep anterior lamellar keratoplasty and evaluate its efficacy for preventing Descemet's membrane folds.
Methods: We calculated the arc diameter of the recipient bed by using the cosine formula and developed a table to aid surgeons in donor punch size selection. To test the usefulness of this formula, we evaluated the development of Descemet's membrane folds in keratoconus patients with very steep corneas (K >60 D). In group 1, deep anterior lamellar keratoplasty surgeries were performed using graft sizes that were determined based on our model (n=31). In group 2, graft sizes were determined based on the empirical judgment of the surgeon without any formal calculation (n=30).
Results: Our theoretical calculations demonstrated that the diameter of donor punch sizes needed to prevent Descemet's membrane fold increases when the cornea is steeper, or the trephine size is larger. We tested the efficacy of this model on the clinical outcome of deep anterior lamellar keratoplasty. The mean age (28.9 ± 10.1 years vs. 32.8 ± 8.3 years, p=0.11) and preoperative K1 (59.2 ± 9.3 D vs. 58.1 ± 9.4 D, p=0.67), K2 (66.2 ± 6.0 D vs. 65.7 ± 7.4 D, p=0.81), and Km values (62.1 ± 7.7 D vs. 61.8 ± 8.1 D, p=0.88) were similar between the two groups. Three patients developed Descemet's membrane folds in group 2, and none of the patients developed Descemet's membrane folds in group 1. These results supported our theo retical calculations.
Conclusion: Adjustment of donor graft size based on the calculated arc diameter of the recipient bed reduced the development of Descemet's membrane folds after deep anterior lamellar keratoplasty in steep corneas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5935/0004-2749.20200077 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!