A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Loss of Reduction after Cephalomedullary Nail Fixation of Intertrochanteric Femoral Fracture: A Brief Report. | LitMetric

Objective: At present, cephalomedullary nail is the most frequently used implant in the management of intertrochanteric fractures around the world. The implant design and fixation techniques of the cephalomedullary nail have been continuously improved to ensure uncomplicated bone union during the past decade. However, a degree of reduction loss during bone healing is still not rare in clinical work. Many attributed this complication to misoperation during the surgery and hold that a series of techniques and tips could help to avoid the loss of reduction. However, until now there has been no research to explore whether the reduction loss after the operation can be fully prevented in the best cases. The purposes of the study are as follows: (i) to evaluate the efficiency of the current established CMN techniques; (ii) to quantify the loss of reduction under an appropriately implanted CMN to anatomically realigned intertrochanteric fractures; and (iii) to explore the possible underlying causes for the inevitable loss of reduction.

Methods: In the retrospective study, 163 consecutive cases with the intertrochanteric fractures fixed with standard cephalomedullary nail technique were reviewed. The anatomical reduction and optimal positioning of the nail were confirmed by postoperative imaging. The fracture types ranged from 31-A1.1-2.3 according to the OTA/AO fracture classification. One hundred and fifteen cases with stable fracture types (31A1.1-2.1) were allocated to Group A, and 48 cases with unstable 31A2.2-2.3 fracture types were allocated to Group B. The radiological measurements included femoral neck shortening, loss of the neck-shaft angle, cutout, and cut-through of the blade. The outcomes between postoperative and 1 year after the operation were evaluated and compared.

Results: The patients consisted of 66 males and 97 females with an average age of 69.4 (range: 46-78, SD: 14.6) years. At the 1-year follow-up, no fixation failure or nonunion was observed in each group. The mean femoral neck shortening and loss of the neck-shaft angle were 4.47 mm (range: 0.43-17.68, SD: 3.71) and 5.4° (range: 0.51-19.10, SD: 3.58) separately. The mean cutout and cut-through were 1.84 mm (range: 0.24-11.30, SD: 2.33) and 1.25 mm (range: 0.51-10.29, SD: 1.74). The average femoral neck shortening and loss of the neck-shaft angle were higher in Group B than Group A. Among the 23 cases with the femoral neck shortening more than 10 mm, 19 cases (16.5%) were from Group A and four cases (8.3%) were from Group B. There were nine (7.8%) cases with the loss of the neck-shaft angle more than 10° in Group A and six (12.5%) cases in Group B.

Conclusions: Current established CMN techniques are efficient in treating intertrochanteric femoral fracture. However, even with currently consensual techniques of cephalomedullary nail, the process of fracture healing still risks the loss of reduction, although the migration of the blade could be minimized. This situation may associate with the intrinsic design of the CMN and further improvement is still needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7767684PMC
http://dx.doi.org/10.1111/os.12828DOI Listing

Publication Analysis

Top Keywords

cephalomedullary nail
20
loss reduction
16
femoral neck
16
neck shortening
16
loss neck-shaft
16
neck-shaft angle
16
intertrochanteric fractures
12
fracture types
12
group cases
12
shortening loss
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!