A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Contribution of Magnetic Resonance Imaging in Determining Lumpectomy Cavity in Breast Radiotherapy. | LitMetric

Background: Accurate localization of the lumpectomy cavity is important for breast cancer radiotherapy after breast-conserving surgery (BCS), but the LC localization based on CT is often difficult to delineate accurately. The study aimed to compare CT-defined LC planning to MRI-defined findings in the supine position for higher soft-tissue resolution of MRI.

Methods: Fifty-nine breast cancer patients underwent radiotherapy CT planning in supine position followed by MR imaging on the same day. LC was contoured by the radiologist and radiation oncologist together by CT and MRI separately. T2 weighted MR images and tomography findings were combined and the LC volume, mean diameter and the longest axis length were measured after contouring. Subsequently, patients were divided into two groups according to seroma in LC and the above-mentioned parameters were compared.

Results: We did not find any statistically significant difference in the LC volume, mean diameter and length at the longest axis between CT and MRI but based on the presence or absence of seroma, statistically significant differences were found in the LC volumes and the length at the longest axis of LC volumes.

Conclusion: We believe that the supine MRI in the same position with CT will be more effective for radiotherapy planning, particularly in patients without a seroma in the surgical cavity.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1573405615666191008162447DOI Listing

Publication Analysis

Top Keywords

longest axis
12
lumpectomy cavity
8
cavity breast
8
breast cancer
8
supine position
8
radiotherapy planning
8
volume diameter
8
length longest
8
contribution magnetic
4
magnetic resonance
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!