A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

USB capsule endoscope for retrograde imaging of the esophagus. | LitMetric

USB capsule endoscope for retrograde imaging of the esophagus.

J Biomed Opt

Comenius University in Bratislava, Department of Gastroenterology, Jessenius Faculty of Medicine in, Slovakia.

Published: October 2020

Significance: Endoscopes represent electro-optical devices that are used to visualize internal body cavities. The specialized endoscopic procedure of the upper gastrointestinal tract from the esophagus down to the duodenum is called an esophagogastroduodenoscopy.

Aim: We bring our newly developed capsule endoscopy device as a promising alternative diagnostic method for visualization of the upper gastrointestinal tract.

Approach: Capsule endoscopy has become an attractive method that uses a tiny wireless camera to take pictures of the digestive tract. Existing esophageal capsule endoscopy does not allow a retrograde view of the esophagus while retrograde scanning can provide information on the esophageal pathology.

Results: In comparison to the existing esophageal capsule endoscopy, our system is much simpler and cheaper due to the need for fewer electronic devices. Moreover, its use is not limited by the capacity of the batteries used by existing capsule endoscopes. The new esophageal endoscopic system was created by combining the universal serial bus (USB) endoscope module with the thin power wires that are routed through the USB port to the computer.

Conclusions: The endoscope was tested on a volunteer without any side effects such as nausea, belching, and general discomfort. The examination of the patient is performed in a sitting position and the patient discomfort during the examination is minimal so it can be performed without anesthesia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7569471PMC
http://dx.doi.org/10.1117/1.JBO.25.10.106002DOI Listing

Publication Analysis

Top Keywords

capsule endoscopy
16
upper gastrointestinal
8
existing esophageal
8
esophageal capsule
8
discomfort examination
8
capsule
5
usb capsule
4
capsule endoscope
4
endoscope retrograde
4
retrograde imaging
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!