A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rate of true recurrent implantation failure is low: results of three successive frozen euploid single embryo transfers. | LitMetric

Objective: To study the true prevalence of recurrent implantation failure.

Design: Retrospective cohort study.

Setting: A private assisted reproductive technology center.

Patient(s): Women (n = 4,429) with anatomically normal uterus who underwent up to three consecutive frozen euploid single embryo transfers (FE-SETs) were included in the study. Cycles with donor eggs or gestational carriers were excluded.

Intervention(s): None.

Main Outcome Measure(s): Cumulative outcomes from these cycles were analyzed. A logistic regression model was used to assess the differences of outcomes between first, second, and third FE-SET and a Kaplan-Meier curve as used to analyze cumulative implantation rate.

Result(s): The mean age of the patients included in the study was of 35.4 years. The sustained implantation rates of the first, second, and third FE-SET were 69.9%, 59.8%, and 60.3% per transfer, respectively. The cumulative sustained implantation rate after up to three consecutive FE-SET was 95.2%. The live birth rates after the first, second, and third FE-SET were 64.8%, 54.4%, and 54.1% per transfer, respectively. The cumulative live birth rate after up to three consecutive FE-SET was 92.6%. The miscarriage rate after observing a positive heartbeat was not different between the first (7.2%), second (8.8%), and third (12.7%) FE-SET.

Conclusion(s): Our findings suggest that true recurrent implantation failure is rare. For those patients with the ability to make euploid blastocysts, <5% would fail to achieve a clinical pregnancy with three embryos transferred. It remains to be further investigated whether this threshold identifies a truly recalcitrant group or simply a statistical certainty based on random variation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fertnstert.2020.07.002DOI Listing

Publication Analysis

Top Keywords

recurrent implantation
12
three consecutive
12
second third
12
third fe-set
12
true recurrent
8
implantation failure
8
frozen euploid
8
euploid single
8
single embryo
8
embryo transfers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!