To investigate the efficacy and safety of left bundle branch area pacing (LBBaP) with the new simplified approach (nine-partition method). A total of 118 patients with clinical indications and received pacemaker implantation from December 1, 2018 to December 31, 2019 in Beijing Anzhen Hospital were enrolled. LBBaP was performed with the nine-partition method (in the right anterior oblique 30° position, the ventriculogram was divided into nine partitions and the initial implant sites were located in the lower base 1/3 partitions). In X-ray image, the 3830 lead is located in the left bundle branch area, the unipolar pacing QRS wave is in the form of right bundle branch block, and the peak time from stimulation to left ventricular activation<90 ms is defined as successful operation. The clinical characters, such as the methods of venipuncture, electrode parameters, operation duration, fluoroscopy duration, the peak time from stimulation to left ventricular, pacemaker types, surgical success rate, complications, and immediate postoperative ECG parameters were collected. The patients were followed up after the operation, and the electrode parameters and postoperative complications were recorded. This study is a retrospective study. There were 62 (52.5%) male patients in this cohort, the average age was (65.9±13.4) years old,and there were 49(41.5%) sick sinus syndrome, 6(5.1%) abnormal sinus node and atrioventricular node simultaneously, 63(53.4%) atrioventricular block, 26(22.0%) atrial fibrillation, 20(16.9%) cardiomyopathy; the baseline duration of QRS was (109.21±39.03) ms. Successful LBBaP was achieved in 109 patients with"nine-partition method"and the success rate was 92.4%; 104 patients (95.5%) were axillary vein puncture, 5 (4.6%) were subclavian vein puncture; the operation duration was (80.3±23.0) min, the fluoroscopy duration was (12.29±5.13) min; the QRS duration after LBBaP was (116.36±18.11) ms. The threshold of the left bundle branch (LBB) lead was (0.92±0.63) V, the R wave amplitude was (10.60±5.04) mV and the impedance was (798.71±194.90) Ω. In 1 V pacing, the peak time from stimulation to left ventricular activation was (67.91±12.15) ms, and in 5 V pacing was (67.52±12.45) ms; 1 case (0.9%) with a single-chamber pacemaker implanted, 106 cases (97.3%) with dual-chamber pacemaker and 2 cases (1.8%) with three-chamber pacemakers. There were no hematomas, pneumothorax, hemothorax, electrode dislocation, infection, and capsular hemorrhage and other serious surgery-related complications during the operation. A total of 97 patients (89.0%) were followed up for (6.21±2.90) months. The electrode parameters of all patients were stable and no complications observed. The LBBaP with nine-partition method is a simple, safe and effective physiological pacing approach. However, its long-term effect still needs to be further verified.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn112148-20200520-00414DOI Listing

Publication Analysis

Top Keywords

bundle branch
16
left bundle
12
branch area
12
area pacing
8
nine-partition method
8
[feasibility safety
4
safety simplified
4
left
4
simplified left
4
bundle
4

Similar Publications

Background: In adolescents and adults with tetralogy of Fallot (TOF), right ventricle (RV) electromechanical dyssynchrony (EMD) due to right bundle branch block (RBBB) is associated with reduced exercise capacity and RV dysfunction. While the development of RBBB following surgical repair of tetralogy of Fallot (rTOF) is a frequent sequela, it is not known whether EMD is present in every patient immediately following rTOF. The specific timing of the onset of RBBB following rTOF therefore provides an opportunity to assess whether acute RBBB is associated with the simultaneous acquisition of EMD.

View Article and Find Full Text PDF

Ventricular Depolarization Abnormalities and Their Role in Cardiac Risk Stratification - A Narrative Review.

Rev Cardiovasc Med

January 2025

Department of Cardiovasculair Sciences, KU Leuven, 3000 Leuven, Belgium.

Ventricular depolarization refers to the electrical activation and subsequent contraction of the ventricles, visible as the QRS complex on a 12-lead electrocardiogram (ECG). A well-organized and efficient depolarization is critical for cardiac function. Abnormalities in ventricular depolarization may indicate various pathologies and can be present in all leads if the condition is general, or in a subgroup of anatomically contiguous leads if the condition is limited to the corresponding anatomic location of the heart.

View Article and Find Full Text PDF

Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC) is a right ventricular disease caused by desmosomal gene mutations leading to fibro-fatty replacement of the myocardium causing ventricular arrhythmias such as ventricular tachycardia (VT). A 59-year-old female presented with new onset VT manifesting as shortness of breath and chest discomfort. Diagnostic workup revealed right ventricular dilation/dysfunction on echocardiogram, VT with left bundle branch block (LBBB) and diffuse T wave inversions (TWIs) on EKG.

View Article and Find Full Text PDF

Background: Arrhythmogenic cardiomyopathy (ACM) is an inherited cardiac disease characterized by fibrofatty replacement of ventricular myocardium. Ventricular arrhythmia and sudden cardiac death (SCD) are the main clinical manifestations. ACM was previously called arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D).

View Article and Find Full Text PDF