A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mitigation of indoor air pollutants using Areca palm potted plants in real-life settings. | LitMetric

Deterioration of indoor air quality (IAQ) has become a serious concern as people spend lots of time indoors and prolonged pollution exposure can result in adverse health outcomes. Indoor plants can phytoremediate a wide variety of indoor contaminants. Nonetheless, few experiments have demonstrated their efficacy in real-time environments. Therefore, the present study aims to experimentally assess the efficiency of Areca palm potted plants in phytoremediation of primary indoor air pollutant viz. total volatile organic compounds (TVOCs), carbon dioxide (CO), and carbon monoxide (CO) levels from real-world indoor spaces, for the first time. Four discrete naturally ventilated experimental sites (I-IV) situated at the Council of Scientific and Industrial Research- Institute of Himalayan Bioresource Technology (CSIR-IHBT) were used. For over a period of 4 months, the sites were monitored using zero plants as a control (1-4 week), three plants (5-8 week), six plants (9-12 week), and nine plants (13-16 week), respectively. Present results indicate that Areca palm potted plants can effectively reduce the TVOCs, CO, and CO levels by 88.16% in site IV, 52.33% and 95.70% in site III, respectively. The current study concluded that Areca palm potted plants offer an efficient, cost-effective, self-regulating, sustainable solution for improving indoor air quality and thereby human well-being and productivity in closed and confined spaces.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-020-11177-1DOI Listing

Publication Analysis

Top Keywords

indoor air
16
areca palm
16
palm potted
16
potted plants
16
plants
9
air quality
8
indoor
6
mitigation indoor
4
air
4
air pollutants
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!