Background: Heparin induced thrombocytopenia (HIT) is reported at a variable rate in extracorporeal membrane oxygenation (ECMO) patients. A critical factor impacting platelet factor-4 (PF4)-heparin antibody formation is plasma PF4 concentration. We hypothesized that PF4 concentration would be increased during veno-arterial (VA) ECMO.
Methods: Plasma PF4 concentration was measured during the first 5 ECMO days in 20 VA ECMO patients and 10 control plasma samples. PF4-heparin ratios were estimated using an assumed heparin concentration of 0.4 IU/mL. This correlates with an activated partial thromboplastin time of 60 to 80 seconds, which is the anticoagulation target in our center.
Results: Twenty VA ECMO patients were enrolled, 10 of which had pulmonary embolism. Median PF4 concentration was 0.03 µg/mL [0.01, 0.13] in control plasma. Median PF4 concentration was 0.21 µg/mL [0.12, 0.34] on ECMO day 1 or 2, 0.16 µg/mL [0.09, 0.25] on ECMO day 3, and 0.12 µg/mL [0.09, 0.22] on ECMO day 5. Estimated median PF4-heparin ratios were 0.04, 0.03, and 0.02 respectively. Two patients (10%) developed HIT that was confirmed by serotonin release assay. PF4 concentration did not differ significantly in these patients compared to non-HIT patients (p = 0.37). No patient had an estimated PF4-heparin ratio between 0.7 and 1.4, which is the reported optimal range for PF4-heparin antibody formation.
Conclusion: Our data suggest that PF4 concentration is mildly elevated during VA ECMO compared to control plasma. Estimated PF4-heparin ratios were not optimal for HIT antibody formation. These data support epidemiologic studies where HIT incidence is low during VA ECMO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0267659120965104 | DOI Listing |
Vaccines (Basel)
December 2024
Institut für Transfusionsmedizin, Universitätsmedizin Greifswald, 17489 Greifswald, Germany.
Background/objectives: Adenoviral vector-based vaccines against COVID-19 rarely cause vaccine-induced immune thrombocytopenia and thrombosis (VITT), a severe adverse reaction caused by IgG antibodies against platelet factor 4 (PF4). To study VITT, patient samples are crucial but have become a scarce resource. Recombinant antibodies (rAbs) derived from VITT patient characteristic amino acid sequences of anti-PF4 IgG are an alternative to study VITT pathophysiology.
View Article and Find Full Text PDFTransfusion
January 2025
Research and Development, Australian Red Cross Lifeblood, Alexandria, New South Wales, Australia.
Background: Whole blood (WB) is increasingly being used for resuscitation of trauma patients. Although platelet-, red blood cell (RBC)- and plasma-specific parameters in cold-stored WB are well characterized, there has been limited investigation of biological response modifiers (BRMs), which may induce adverse reactions in recipients. The aim of this study was to evaluate the quality and function of RBC, platelets, plasma proteins, and BRMs in cold-stored WB during storage.
View Article and Find Full Text PDFSci Rep
November 2024
Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka, 573-1010, Japan.
Ulcerative colitis (UC) is a refractory, chronic inflammatory bowel disease of unknown etiology. Although platelets are activated in UC, their relevance in pathophysiology remains unclear. We analyzed the correlation of platelet activation and platelet-monocyte complexes (PMCs) with severity of mucosal inflammation using the Mayo endoscopic subscore (MES).
View Article and Find Full Text PDFSci Rep
October 2024
Science for Life Laboratory, Department of Medical Biochemistry and Microbiology, Uppsala University, Uppsala, Sweden.
While Coronavirus disease 2019 (COVID-19) vaccines have proven to be both effective and generally safe, rare but severe adverse events following immunization (AEFIs) are described. Autoantibodies to platelet factor-4 are associated with catastrophic thrombotic AEFIs, but comprehensive investigations of other autoantibodies are lacking. We aimed to detect and describe autoantibodies targeting coagulation-related proteins in a population-wide cohort (SWEDEGENE) including AEFIs attributed to COVID-19 vaccines in Sweden.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
October 2024
Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA.
To develop standardized in vitro thrombogenicity test methods for evaluating medical device materials, three platelet activation biomarkers, beta-thromboglobulin (β-TG), platelet factor 4 (PF4), soluble p-selectin (CD62P), and a plasma coagulation marker, thrombin-antithrombin complex (TAT), were investigated. Whole blood, drawn from six healthy human volunteers into Anticoagulant Citrate Dextrose Solution A was recalcified and heparinized over a concentration range of 0.5-1.