Prediction of Human Inhibition Brain Function with Inter-Subject and Intra-Subject Variability.

Brain Sci

Department of Biological Science and Technology, College of Biological Science and Technology, National Chiao Tung University, Hsinchu 300, Taiwan.

Published: October 2020

The stop signal task has been used to quantify the human inhibitory control. The inter-subject and intra-subject variability was investigated under the inhibition of human response with a realistic environmental scenario. In present study, we used a battleground scenario where a sniper-scope picture was the background, a target picture was a go signal, and a nontarget picture was a stop signal. The task instructions were to respond on the target image and inhibit the response if a nontarget image appeared. This scenario produced a threatening situation and endorsed the evaluation of how subject's response inhibition manifests in a real situation. In this study, 32 channels of electroencephalography (EEG) signals were collected from 20 participants during successful stop (response inhibition) and failed stop (response) trials. These EEG signals were used to predict two possible outcomes: successful stop or failed stop. The inter-subject variability (between-subjects) and intra-subject variability (within-subjects) affect the performance of participants in the classification system. The EEG signals of successful stop versus failed stop trials were classified using quadratic discriminant analysis (QDA) and linear discriminant analysis (LDA) (i.e., parametric) and K-nearest neighbor classifier (KNNC) and Parzen density-based (PARZEN) (i.e., nonparametric) under inter- and intra-subject variability. The EEG activities were found to increase during response inhibition in the frontal cortex (F3 and F4), presupplementary motor area (C3 and C4), parietal lobe (P3 and P4), and occipital (O1 and O2) lobe. Therefore, power spectral density (PSD) of EEG signals (1-50Hz) in F3, F4, C3, C4, P3, P4, O1, and O2 electrodes were measured in successful stop and failed stop trials. The PSD of the EEG signals was used as the feature input for the classifiers. Our proposed method shows an intra-subject classification accuracy of 97.61% for subject 15 with QDA classifier in C3 (left motor cortex) and an overall inter-subject classification accuracy of 71.66% ± 9.81% with the KNNC classifier in F3 (left frontal lobe). These results display how inter-subject and intra-subject variability affects the performance of the classification system. These findings can be used effectively to improve the psychopathology of attention deficit hyperactivity disorder (ADHD), obsessive-compulsive disorder (OCD), schizophrenia, and suicidality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7600619PMC
http://dx.doi.org/10.3390/brainsci10100726DOI Listing

Publication Analysis

Top Keywords

intra-subject variability
20
eeg signals
20
inter-subject intra-subject
12
response inhibition
12
signal task
8
picture signal
8
successful failed
8
classification system
8
failed trials
8
discriminant analysis
8

Similar Publications

The aim of this study was to determine the minimum playing time in matches required to produce reliable acceleration - speed (AS) profiles from global navigation satellite system (GNSS) data. The playing time of 25 professional rugby union players was recorded using GNSS technology and segmented into four sections from 40, 80, 120 and 160 minutes of play. For each interval, the impact of integrating new match data on the AS profile was assessed, aiming to identify the saturation point where additional data did not induce significant changes in the profile outputs.

View Article and Find Full Text PDF

The quest for noninvasive early markers for sensorineural hearing loss (SNHL) has yielded diverse measures of interest. However, comprehensive studies evaluating the test-retest reliability of multiple measures and stimuli within a single study are scarce, and a standardized clinical protocol for robust early markers of SNHL remains elusive. To address these gaps, this study explores the intra-subject variability of various potential electroencephalogram- (EEG-) biomarkers for cochlear synaptopathy (CS) and other SNHL-markers in the same individuals.

View Article and Find Full Text PDF

Objectives: This two-part pilot study investigated the feasibility of using a frequency selectivity measure (T) to develop a novel hearing screening test for cooperative adults. Study 1 determined the optimal masker level, while Study 2 assessed the reliability of a self-administered T test prototype performed at the selected masker level.

Design And Study Sample: Study 1 (normal hearing,  = 20) examined masker-level effects on T using a manual threshold determination method from an earlier study.

View Article and Find Full Text PDF

Reaching movements are essential for daily tasks and they have been widely investigated through kinematic, kinetic, and electromyographic (EMG) analyses. Recent studies have suggested that the central nervous system simplifies control of reaching movements by using muscle synergies. An alternative approach is to investigate how EMG activity reflects at theneural level with the representation of spinal maps that visualize the spatiotemporal activity of motoneuronal pools.

View Article and Find Full Text PDF

This study aimed to reveal individual differences between the speeds of the hand and ball and clarify the factors affecting those differences. Motion data from 20 highly skilled baseball pitchers, captured using a 16-camera motion analysis system with a sampling frequency of 1,000 hz, were used for correlation and hierarchical linear model analyses. For the hierarchical linear models, the speed of the metacarpophalangeal joint was the independent variable in the 1 level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!