Minimally invasive mitral valve repair.

Indian J Thorac Cardiovasc Surg

University Department for Cardiac Surgery, Leipzig Heart Center, Struempellstrasse 39, 04289 Leipzig, Germany.

Published: January 2020

Minimally invasive mitral valve (MV) repair is being increasingly performed over the last 2 decades due to the constantly growing patient demand, since it offers a shorter recovery, less restriction and faster return to normal physical activities, reduction in pain, and superior cosmetic results. However, such procedures have to be performed through small incisions which limit visualization and the freedom of movement of the surgeon, in contrast to conventional operations that are performed through a sternotomy. Therefore, special long surgical instruments are required, and visualization is usually enhanced with advanced port-access two-dimensional (2D) or three-dimensional (3D) thoracoscopic cameras. This makes performance of a minimally invasive MV repair more challenging for the surgeon and is thereby associated with a steep learning curve. Nonetheless, the vast majority of patients who require MV repair are usually good candidates for this less invasive technique, though adequate patient selection is of utmost importance for success. Concomitant cardiac procedures such as ablation surgery for atrial fibrillation or right-sided interventions such as tricuspid valve surgery, heart tumor resection, and atrial septal defect closure can easily be performed using this approach. Short- and long-term results after minimally invasive MV repair are excellent and comparable with those achieved through a sternotomy approach. There are few drawbacks associated with minimally invasive MV repair such as the high technical demands of working through a constrained space and development of complications associated with peripheral cannulation and seldom unilateral pulmonary edema. Nonetheless, high-volume centers have been able to achieve similar operating times, postoperative complication rates, and mid-/long-term outcomes to those obtained through conventional sternotomy. Up-to-date evidence is needed in order to improve recommendations supporting minimally invasive MV repair. Future innovations should concentrate on decreasing complexity and improving reproducibility of minimally invasive procedures in low-volume centers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7525482PMC
http://dx.doi.org/10.1007/s12055-019-00843-wDOI Listing

Publication Analysis

Top Keywords

minimally invasive
28
invasive repair
16
invasive mitral
8
mitral valve
8
valve repair
8
minimally
7
repair
7
invasive
7
repair minimally
4
repair increasingly
4

Similar Publications

Introduction: Aneurysmal bone cysts are locally aggressive bone lesions. The aim of this study was to evaluate safety and effectiveness of radio-opaque gelified ethanol sclerotherapy in treating primary aneurysmal bone cyst.

Materials And Methods: In this single-center, retrospective study (January 1st, 2012, to June 30th, 2024), 32 patients with primary aneurysmal bone cysts were treated with percutaneous sclerotherapy using radio-opaque gelified ethanol at various skeletal sites.

View Article and Find Full Text PDF

Introduction: Altered vascular microcirculation is recognized as a risk factor for anastomotic leakage (AL) in colorectal surgery. However, few studies evaluated its impact on AL using different devices, with heterogeneous results. The present study reported the initial experience measuring gut microcirculatory density and flow with the aid of incidence dark-field (IDF) videomicroscopy (Cytocam, Braedius, Amsterdam, The Netherlands) comparing its operative outcome using a propensity score matching (PSM) model based on age, gender, and Charlson Comorbidity Index (CCI).

View Article and Find Full Text PDF

Short-term outcomes of mesh-suture repair in the treatment of ventral hernias: a single-center study.

Surg Endosc

January 2025

Division of Minimally Invasive and Bariatric Surgery, Penn State Health Milton S. Hershey Medical Center, 500 University Drive, Hershey, PA, 17033, USA.

Background: Defect closure with mesh suture is a novel technique for hernia repair. Originally described as the construction of lightweight macroporous polypropylene mesh strips as a suture material, it is now available as an FDA-approved product. Mesh suture better distributes tensile forces and reduces fascial tearing compared to traditional suture but requires less implanted material and tissue dissection compared to planar mesh.

View Article and Find Full Text PDF

Assessing parental aesthetic acceptability of Silver Diamine Fluoride (SDF) staining is crucial for its potential implementation in paediatric dentistry in different regions. This study aimed to compare aesthetic perceptions and acceptance of SDF staining between Spanish and Italian parents, and assess weather acceptability is influenced by location, child's cooperation, or demographic background. A cross-sectional comparative study was conducted among Spanish and Italian parents at three university dental clinics, using a validated Italian version of the questionnaire "Parental perceptions of Silver Diamine Fluoride Dental Color Changes".

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!