Visual performance after bilateral toric extended depth-of-focus IOL exchange targeted for micromonovision.

J Cataract Refract Surg

From the Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.

Published: October 2020

Purpose: To evaluate overall patient satisfaction, spectacle independence, binocular visual acuity, rotational stability, prevalence of optical phenomena, and decentration and tilt after bilateral toric extended depth-of-focus intraocular lens (EDOF IOL) implantation targeted for micromonovision.

Setting: Department of Ophthalmology, Hanusch Hospital, Vienna, Austria.

Design: Prospective case series.

Methods: The study included 52 eyes of 26 patients with regular corneal astigmatism from 0.75 to 2.60 diopters (D) that were implanted bilaterally with a toric EDOF IOL targeted for micromonovision. Postoperative visual acuity, astigmatism reduction, rotation, tilt, decentration, spectacle independence, patient satisfaction, and photic phenomena were assessed.

Results: For the 52 eyes studied, binocular means expressed in logarithm of the minimum angle resolution for postoperative corrected distance, uncorrected distance, uncorrected intermediate, and uncorrected near visual acuities were -0.10 (±0.12), -0.01 (±0.13), 0.01 (±0.14), and 0.13 (±0.14), respectively. Mean refractive astigmatism reduction was 1.31 ± 0.67 D resulting in a mean refractive cylinder of 0.47 ± 0.46 D at the 3-month visit. Mean postoperative rotation was 3.5 ± 3.5 degrees, at the 3-month time point. Most prevalent dysphotopsia were halos, starburst, and glare affecting 6 (23%), 6 (23%), and 5 (19%) of 26 patients, respectively; 20 (77%) of 26 patients reported spectacle independence, with 19 (95%), 19 (95%), and 14 (70%) of 20 patients questioned being satisfied with distance, intermediate, and near vision, respectively.

Conclusions: Toric EDOF IOL implantation targeted for micromonovision resulted in reliable reduction of preoperative astigmatism with a high degree of postoperative rotational predictability and centration, enabling functional distance, intermediate, and near vision, which manifested itself in high patient satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1097/j.jcrs.0000000000000290DOI Listing

Publication Analysis

Top Keywords

targeted micromonovision
12
patient satisfaction
12
spectacle independence
12
edof iol
12
bilateral toric
8
toric extended
8
extended depth-of-focus
8
visual acuity
8
iol implantation
8
implantation targeted
8

Similar Publications

Purpose: To evaluate visual outcomes following bilateral implantation of the RayOne EMV intraocular lens with targeted micro-monovision.

Setting: Southend Private Hospital, UK.

Design: Retrospective cohort.

View Article and Find Full Text PDF

To investigate the effects of the application of a low addition refractive multifocal intraocular lens (IOL) using the micromonovision design in the non-dominant eye with different degrees of preset myopia on the visual acuity, visual function and visual quality after bilateral cataract surgery. In this randomized controlled trial, patients who were proposed to undergo bilateral phacoemulsification combined with rotational asymmetric refractive IOL (MF15 IOL) implantation at the First Affiliated Hospital of Zhengzhou University between September 2020 and August 2022 were included. All patients were divided into three groups using the random number method.

View Article and Find Full Text PDF

Early Outcomes of Two Treatment Modes of PresbyLASIK: Monocular vs. Micro-Monovision.

Clin Ophthalmol

November 2022

Wollongong Eye Specialists, Wollongong, Australia.

Purpose: To report the visual, refractive and subjective outcomes of presbyLASIK for the correction of presbyopia.

Methods: Monocular (20 eyes) or micro-monovision (12 eyes) presbyLASIK was performed on a total of 32 eyes in 16 patients (50% female, average age 55±4.6 years) using the Zeiss VisuMax 400Hz femtosecond and Schwind Amaris 1050RS excimer laser platform.

View Article and Find Full Text PDF

Visual performance after bilateral toric extended depth-of-focus IOL exchange targeted for micromonovision.

J Cataract Refract Surg

October 2020

From the Vienna Institute for Research in Ocular Surgery, A Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria.

Purpose: To evaluate overall patient satisfaction, spectacle independence, binocular visual acuity, rotational stability, prevalence of optical phenomena, and decentration and tilt after bilateral toric extended depth-of-focus intraocular lens (EDOF IOL) implantation targeted for micromonovision.

Setting: Department of Ophthalmology, Hanusch Hospital, Vienna, Austria.

Design: Prospective case series.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical outcome of blended vision combined with micromonovision (MMBV) using a +4 diopter (D) addition power (add) diffractive intraocular lens (MIOL) and a +2.75D add MIOL with a myopic target of -0.5 D.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!