The purpose of this study was to evaluate the effect of a hydrogel spacer on intrafractional prostate motion during CyberKnife treatment. The retrospective study enrolled 24 patients (with the hydrogel spacer = 12, without the hydrogel spacer = 12) with two fiducial markers. Regarding intrafractional prostate motion, the offset values (mm) of three axes (X-axis; superior [+] to inferior [-], Y-axis; right [+] to left [-], Z-axis; posterior [+] to anterior [-]) obtained from fiducial markers position between a digitally reconstructed radiographs images and live images in the Target Locating System were used, and extracted from generated log files. The mean values of the offset and each standard deviation were calculated for each patient, and both the groups were compared. For all the patients, a total of 2204 offset values and timestamps (without the hydrogel spacer group: 1065, with the hydrogel spacer group: 1139) were recorded for the X-, Y-, and Z-axes, respectively. The offset values (mean ± standard deviation) for the X-, Y-, and Z-axes were -0.04 ± 0.92 mm, -0.03 ± 0.97 mm (P = 0.66), 0.02 ± 0.51, -0.02 ± 0.49 mm (P = 0.50), and 0.56 ± 0.97 mm, 0.34 ± 1.07 mm (P = 0.14), in patients inserted without or with the hydrogel spacer, respectively. There was no effect of a hydrogel spacer on the intrafractional prostate motion in the three axes during CyberKnife treatment for prostate cancer.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592967 | PMC |
http://dx.doi.org/10.1002/acm2.13005 | DOI Listing |
J Mater Chem B
January 2025
Laboratory of Organic and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Humboldtstr. 10, 07743 Jena, Germany.
Hydrogels based on supramolecular assemblies offer attractive features for biomedical applications including injectability or versatile combinations of various building blocks. We here investigate a system combining benzenetrispeptides (BTP), which forms supramolecular fibers, with polymer polyethylene oxide (PEO) forming a dense hydrophilic shell around the fibers. Hydrogels are created through the addition of a bifunctional crosslinker (CL).
View Article and Find Full Text PDFStrahlenther Onkol
December 2024
Department of Urology, Ofuna Chuo Hospital, Kamakura, Kanagawa, Japan.
Purpose: Whole-prostate dose escalation in stereotactic body radiotherapy (SBRT) for localized prostate cancer (PCa) can improve oncological outcomes, albeit at the cost of increased toxicity. A focal boost to the dominant intraprostatic lesion (DIL) is gaining interest as an alternative approach. Herein, we investigate the safety and efficacy of this approach.
View Article and Find Full Text PDFCarbohydr Polym
February 2025
State key laboratory base of eco-chemical Engineering, College of Chemical Engineering, Qingdao University of Science and Technology, 53 Zhengzhou Road, Qingdao, Shandong province 266042, PR China. Electronic address:
A 75-year-old man presented with hematochezia. He had been diagnosed with prostate cancer (stage 1) 1 month previously and had undergone gold marker injection and hydrogel spacer insertion 3 weeks previously to prepare for radiotherapy. Hydrogel spacer insertion is a safe procedure that can prevent the side effects of radiotherapy for prostate cancer.
View Article and Find Full Text PDFAdv Radiat Oncol
December 2024
Department of Radiation Oncology, New York University Langone Medical Center, New York, New York.
Purpose: Rectal spacers have gained popularity as a dose-sparing material for prostate cancer radiation therapy (RT). However, the procedure can be associated with unintended rectal wall infiltration (RWI) of the spacer gel. We therefore classified RWI severity as a function of depth and explored its association with rectal toxicity using a data set from prostate cancer patients treated with RT on a prospective randomized clinical trial (RCT).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!