Impact of ictal subtraction SPECT and PET in presurgical evaluation.

Acta Neurol Scand

Comprehensive Epilepsy Program, Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

Published: March 2021

AI Article Synopsis

  • The study examined how ISSPECT and PET imaging contribute to decision-making in epilepsy surgery for patients with resistant focal epilepsy.
  • About 106 patients were analyzed, revealing that concordance with clinical consensus was higher for ISSPECT (76%) than for PET (79%), but both were important in evaluating surgical options.
  • The findings suggest that concordance with PET imaging increases the likelihood of proceeding to further monitoring, while concordance with ISSPECT and MRI correlates with better surgical outcomes.

Article Abstract

Objective: To assess the relative contribution of ictal subtraction single-photon emission computed tomography (ISSPECT) and F-fluorodeoxyglucose positron emission tomography computed tomography (PET) in epilepsy surgery decision making.

Materials And Methods: A retrospective 3-year study of consecutive patients with resistant focal epilepsy who underwent ISSPECT and PET to evaluate to what extent these modalities influence decisions in epilepsy surgery and outcomes. ISSPECT imaging was performed in 106 patients and 58 (55%) had PET also. The clinical consensus (ClinC) was the final arbiter for decisions. Post-surgical outcomes were collected from follow-up clinics. Non-parametric statistics were used to assess association and logistic regression to evaluate prediction of outcomes.

Results: Of 106 patients, 60 were males (57%). MRI was non-lesional in 46 (43%). Concordance with ClinC was seen in 80 patients (76%) for ISSPECT, in 46 patients (79%) for PET, and in 37 patients (64%) for ISSPECT + PET. Fifty-six patients (53%) were planned for intracranial video-electroencephalography monitoring (IVEM). Those with ClinC-PET concordance were likely to proceed to IVEM (p = 0.02). ClinC-PET concordance and ClinC-ISSPECT concordance did not predict decision to proceed to surgery, but VEM-MRI concordance did in lesional cases (p = 0.018). Forty-five (42%) underwent surgery of which 29 had minimum follow-up for 1 year (mean, 20 months; SD, 8) and 22 (76%) had Engel class I outcomes. ClinC-ISSPECT concordance (p = 0.024) and VEM-MRI concordance (p = 0.016) predicted Engel class I outcomes.

Conclusion: Those with ClinC-PET concordance were more likely to proceed with IVEM. ClinC-ISSPECT concordance and VEM-MRI concordance predicted good surgical outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ane.13362DOI Listing

Publication Analysis

Top Keywords

clinc-pet concordance
12
clinc-isspect concordance
12
vem-mri concordance
12
concordance
10
ictal subtraction
8
computed tomography
8
epilepsy surgery
8
isspect pet
8
106 patients
8
concordance proceed
8

Similar Publications

Impact of ictal subtraction SPECT and PET in presurgical evaluation.

Acta Neurol Scand

March 2021

Comprehensive Epilepsy Program, Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.

Article Synopsis
  • The study examined how ISSPECT and PET imaging contribute to decision-making in epilepsy surgery for patients with resistant focal epilepsy.
  • About 106 patients were analyzed, revealing that concordance with clinical consensus was higher for ISSPECT (76%) than for PET (79%), but both were important in evaluating surgical options.
  • The findings suggest that concordance with PET imaging increases the likelihood of proceeding to further monitoring, while concordance with ISSPECT and MRI correlates with better surgical outcomes.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!