Objectives: This study was performed to assess the association between the dissection length-to-descending thoraco-abdominal aorta length ratio (LLR) and abdominal aortic enlargement (AAE) (≥20% increase in total abdominal aortic volume) after thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection.
Methods: We retrospectively analysed data from 184 consecutive patients with type B aortic dissection who underwent TEVAR from January 2011 to December 2016 at 4 hospitals as part of the Registry Of type B aortic dissection with Utility of STent graft study. Preoperative and postoperative computed tomography angiography images were reviewed to assess the LLR and AAE. Patients were stratified into tertiles according to the pre-TEVAR LLR: 0.7 to <1.0 (n = 61), 1.0 to <1.2 (n = 61) and 1.2 to <1.6 (n = 62). The thoracic and abdominal aorta were divided by the celiac trunk. The cumulative incidence of AAE was estimated using the Kaplan-Meier method. A multivariable Cox proportional hazards model was used to assess the independent association between the preoperative LLR and the post-TEVAR risk of AAE. The nonlinear relationship between the LLR and the risk of post-TEVAR AAE was fitted by the restricted cubic smoothing spline, and the inflection point on the fitting curve was determined using a piecewise linear regression model.
Results: Baseline demographics, clinical features, preoperative anatomic characteristics and implanted devices were similarly distributed among the pre-TEVAR LLR tertile groups. At 24 months post-TEVAR, the estimated cumulative incidence of AAE significantly differed (P < 0.01) by LLR tertile group: 0.10 [95% confidence interval (CI) 0.00-0.21], 0.65 (95% CI 0.45-0.78) and 0.67 (95% CI 0.40-0.82), respectively. The pre-TEVAR LLR was an independent predictor of post-TEVAR AAE [hazard ratio (per unit increase) 1.03, 95% CI 1.01-1.04] following a nonlinear relationship with an inflection point at LLR = 1.0.
Conclusions: The risk of post-TEVAR AAE is highest when the length of the dissection is greater than or equal to the length of the descending aorta (LLR ≥ 1.0).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/icvts/ivaa184 | DOI Listing |
We present the case of a 74-year-old female patient with a 50 mm ascending aortic aneurysm who underwent ascending aorta replacement. During routine open heart surgery, suboptimal flow in the cardiopulmonary bypass circuit, led to the discovery of a type B aortic dissection with substantial flow in the false lumen. Conservative management was chosen, focusing on blood pressure control in the ICU.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
J Thorac Cardiovasc Surg
January 2025
University of Maryland School of Medicine, Division of Cardiothoracic Surgery. Electronic address:
Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.
Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.
A 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.
View Article and Find Full Text PDFCardiovasc Intervent Radiol
January 2025
Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands.
Purpose: To investigate the influence of antithrombotic therapy on occurrence of thrombotic and bleeding complications after endovascular aneurysm repair (EVAR).
Methods: In this retrospective single-center cohort study, patients who underwent elective endovascular aneurysm repair for abdominal aortic aneurysm were categorized into three antithrombotic groups: single antiplatelet therapy (SAPT), anticoagulants, or dual antiplatelet therapy (DAPT). Outcome measures were the incidence of major adverse cardiovascular events (MACE), prosthetic limb occlusions, and bleeding complications during follow-up.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!