Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Most clinical trials of contrast-rebalanced binocular amblyopia treatment used a contrast increment protocol of 10% daily with successful play. Paired with a definition of success requiring only 15-30 min/day of gameplay, this increment protocol could allow children to reach 100% fellow eye contrast in 3-9 hours; however, this may not provide adequate therapeutic time with reduced fellow eye contrast. The purpose of this study was to compare the original protocol against three alternative contrast increment protocols designed to increase the number of treatment hours.
Methods: In this prospective study, 63 amblyopic children (4-10 years; amblyopic eye visual acuity, 20/40-125) were randomly assigned one of four daily contrast increment protocols for 4 weeks, all starting with 20% fellow eye contrast: 10%, 5%, 0%, or 10% for first 4 weeks then reset to 20% and repeat 10% increment for the final 4 weeks. Children played contrast-rebalanced games for 1 hour/day, 5 days/week. Best-corrected visual acuity, stereoacuity, and suppression were assessed at baseline and every 2 weeks until the 8-week outcome visit.
Results: At baseline, mean amblyopic eye best-corrected visual acuity was 0.47 ± 0.14 logMAR (20/60), improving overall 0.14 ± 0.08 logMAR (1.4 lines; P < 0.0001) at 8 weeks. All four protocols resulted in similar improvement in visual acuity (0.13-0.16 logMAR; all Ps < 0.0002). Stereoacuity and suppression also improved (all Ps < 0.05).
Conclusions: None of the new protocols resulted in less improvement than the original 10% contrast increment protocol. Contrast-rebalanced binocular games yielded significant improvements in visual acuity, stereoacuity, and suppression with or without daily contrast increments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8328197 | PMC |
http://dx.doi.org/10.1016/j.jaapos.2020.06.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!