The COVID-19 pandemic has caused an unprecedented human and health crisis. And the shortage of protective equipment, especially the personal protective disposable surgical masks, has been a great challenge. Here, we developed an effective and simple scheme to prolong the lifetime of disposable surgical masks without changing their current structure, which is beneficial to solve the shortage of personal masks. After electrifying the meltblown PP filter by the new-developed single-electrode-based sliding triboelectric nanogenerator (TENG) charge replenishment (NGCR) technology, the processed filter is bipolar charged and has a filtration efficiency beyond 95% for the particulate matter (PM) ranging from PM to PM. Further, we demonstrate the 80 °C dry heating is an effective decontamination method. This method is compatible with single-electrode-based sliding TENG charge replenishment technology. The 80 °C dry heating and the NGCR technology can make up an effective regeneration procedure for the mask. Even after ten cycles of simulated 4 h wearing process and such regeneration procedure, the filtration efficiency of the disposable surgical masks PM is still higher than 95%.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7534667 | PMC |
http://dx.doi.org/10.1016/j.nanoen.2020.105434 | DOI Listing |
Vet Rec
January 2025
Department of Surgery, Anesthesia and Orthopedics of Large Animals, Faculty of Veterinary Medicine, Ghent University, Merelbeke, Belgium.
Background: Reuse of disposable medical products is common practice in veterinary medicine; however, studies on the safety of such reuse are often lacking. This study aimed to determine whether steam sterilisation of disposable surgical gowns compromises their resistance to wet microbial penetration.
Methods: Twenty surgical gowns were removed from their sterile packaging, manipulated, wetted, dried and subsequently repacked and steam sterilised.
Objectives: To study the long-term outcomes of the flexible and navigable suction ureteral access sheath (FANS) in flexible ureteroscopy (FURS). FANS has well-established efficiency and 30-day perioperative safety; however, its influence on pelvicalyceal and ureteric anatomy remains to be investigated.
Methods: This was a prospective study of patients with normal renal anatomy who underwent FURS with FANS for renal stones from April 2023 to August 2024 in 16 centers worldwide.
Adv Health Sci Educ Theory Pract
January 2025
Department of Surgery, University of California San Francisco, 513 Parnassus Avenue S-321, San Francisco, CA, 94143, USA.
The rise of robotic surgery has been accompanied by numerous educational challenges as surgeons and trainees learn skills unique to the robotic platform. Remote instruction is a solution to provide surgeons ongoing education when in-person teaching is not feasible. However, surgical instruction faces challenges from unclear communication.
View Article and Find Full Text PDFInt J Surg
December 2024
Department of Surgery, Maastricht University Medical Center, Maastricht.
Background: The evolution of endoscopic surgery has introduced a multitude of instruments, available in both disposable and reusable variants, influencing practices across various surgical specialties. Instrument selection is complex, considering individual preferences and institutional factors such as costs, instrument performance, and factors related to cleaning and sterilization. Notably, environmental sustainability has gained prominence due to the threat of climate change.
View Article and Find Full Text PDFZhong Nan Da Xue Xue Bao Yi Xue Ban
August 2024
Department of Anesthesiology, Third Xiangya Hospital, Central South University, Changsha 410013, China.
Objectives: Thalamic hematoma patients present with diverse clinical conditions, and treatment approaches vary widely. Currently, the use of disposable portable endoscope surgery has been rapidly adopted in many hospitals, but outcomes can vary significantly. Surgical approaches and techniques for thalamic hematoma often reference those used for basal ganglia hemorrhage, but their effectiveness remains uncertain.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!