A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Early Detection of Cartilage Degeneration: A Comparison of Histology, Fiber Bragg Grating-Based Micro-Indentation, and Atomic Force Microscopy-Based Nano-Indentation. | LitMetric

We have determined the sensitivity and detection limit of a new fiber Bragg grating (FBG)-based optoelectronic micro-indenter for biomechanical testing of cartilage and compared the results to indentation-type atomic force microscopy (IT-AFM) and histological staining. As test samples, we used bovine articular cartilage, which was enzymatically degraded ex vivo for five minutes using different concentrations of collagenase (5, 50, 100 and 500 µg/mL) to mimic moderate extracellular matrix deterioration seen in early-stage osteoarthritis (OA). Picrosirius Red staining and polarization microscopy demonstrated gradual, concentration-dependent disorganization of the collagen fibrillar network in the superficial zone of the explants. Osteoarthritis Research Society International (OARSI) grading of histopathological changes did not discriminate between undigested and enzymatically degraded explants. IT-AFM was the most sensitive method for detecting minute changes in cartilage biomechanics induced by the lowest collagenase concentration, however, it did not distinguish different levels of cartilage degeneration for collagenase concentrations higher than 5 µg/mL. The FBG micro-indenter provided a better and more precise assessment of the level of cartilage degeneration than the OARSI histological grading system but it was less sensitive at detecting mechanical changes than IT-AFM. The FBG-sensor allowed us to observe differences in cartilage biomechanics for collagenase concentrations of 100 and 500 µg/mL. Our results confirm that the FBG sensor is capable of detecting small changes in articular cartilage stiffness, which may be associated with initial cartilage degeneration caused by early OA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7582717PMC
http://dx.doi.org/10.3390/ijms21197384DOI Listing

Publication Analysis

Top Keywords

cartilage degeneration
16
cartilage
9
fiber bragg
8
atomic force
8
articular cartilage
8
enzymatically degraded
8
100 500
8
500 µg/ml
8
cartilage biomechanics
8
collagenase concentrations
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!