Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Alveolar ridge preservation maintains ridge dimensions and bone quality for implant placement. The aim of this randomized controlled clinical study is to compare the use of a human amnion-chorion membrane to a collagen membrane in an exposed-barrier ridge preservation technique. Furthermore, this study will determine if intentional membrane exposure compromises ridge dimensions and bone vitality. Forty-three patients requiring extraction and delayed implant placement were randomly assigned into either the experimental or control group. Twenty-one participants received human amnion-chorion membrane (test) during ridge preservation while 22 participants received the collagen membrane (control). In both groups, demineralized freeze-dried bone allografts were used to graft the socket and primary closure was not achieved. The patients underwent implant placement after an average healing period of 19.5 weeks, and 2.7 × 8-mm core bone specimens were obtained for histomorphometric analyses. The clinical ridge dimensions were measured after extraction and at the time of delayed implant placement. No significant difference was observed in the mean vital bone formation between the experimental (51.72 ± 8.46%) and control (49.96 ± 8.31%; P > .05) groups. The bone height and width did not differ, as determined by clinical measurements (P > .05). Using either a human amnion-chorion membrane or type 1 bovine collagen as the open barrier did not change healing, compromise ridge dimensions, or affect bone vitality between the 2 groups.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/aaid-joi-D-19-00335 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!