Over the last two decades, misuse of 4-fluoroamphetamine (4-FA) became an emerging issue in many European countries. Stimulating effects last for 4-6 hours and can impact psychomotor performance. The metabolism of amphetamine-type stimulants is stereoselective and quantification of (R)- and (S)-enantiomers has been suggested for assessing time of use. To date, no data on enantioselective pharmacokinetics is available for 4-FA in serum samples. An enantioselective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed using a chiral Phenomenex® Lux 3 μm AMP column. Validation of the method showed satisfactory selectivity, sensitivity, linearity (0.5-250 ng/mL), precision and accuracy. Recreational stimulant users orally ingested two doses (100 mg, n = 12; 150 mg, n = 5) of 4-FA. Blood samples were drawn prior to application and over a period of 12 hours after ingestion and analyzed for 4-FA enantiomers. Peak concentrations and corresponding times did not differ significantly between the enantiomers (mean (R)/(S)-ratio at tmax 1.05, 0.85-1.16). With mean 12.9 (8.3-16.1) hours, apparent elimination half-lives (t1/2) were significantly (P < 0.01) longer for (R)-4-FA than for (S)-4-FA (6.0 hours; range 4.4-10.2 hours) and independent of the dose given. Over time, (R)/(S)-concentration-ratios were linearly increasing in all subjects to maximum ratios of 2.00 (1.08-2.77) in the last samples (after 12 hours). The slopes of the (R)/(S)-ratio exhibited marked interindividual differences (0.023-0.157 h-1, mean 0.095 h-1). Ratios higher than 1.60 only appeared earliest after a minimum of 6 hours and therefore suggest the absence of acute drug effects. Different elimination half-lives of enantiomers lead to constantly increasing (R)/(S)-concentration-ratios. Consequently, ratios of 4-FA enantiomers in serum are a promising indicator for assessment of the time of drug consumption.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jat/bkaa156 | DOI Listing |
Methods Mol Biol
January 2025
Laboratory of Analytical Biochemistry & Metabolomics, Biology Centre, Czech Academy of Sciences, České Budějovice, Czech Republic.
A simple analytical workflow is described for gas chromatographic-mass spectrometric (GC-MS)-based chiral profiling of secondary amino acids (AAs) in biological matrices. The sample preparation is carried out directly in aqueous biological sample extracts and involves in situ heptafluorobutyl chloroformate (HFBCF) derivatization-liquid-liquid microextraction of nonpolar products into hexane phase followed by subsequent formation of the corresponding methylamides from the HFB esters by direct treatment with methylamine reagent solution. The (O, N) HFB-butoxycarbonyl-methylamide AA products (HFBOC-MA) are separated on a Chirasil-L-Val capillary column and quantitatively measured by GC-MS operated in selected ion monitoring (SIM) mode.
View Article and Find Full Text PDFBiosens Bioelectron
March 2025
Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen University, Shenzhen, 518060, China; Marshall Laboratory of Biomedical Engineering, Shenzhen Key Laboratory of Nano-Biosensing Technology, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, 518060, China. Electronic address:
Highly ordered ultrathin nanosheets (NSs) of Au(I)-Cys were fabricated through aggregation-induced supramolecular self-assembly triggered by an extended agitation in an alkaline environment. The synthesized Au(I)-Cys NSs exhibited intense luminescence and exceptional chirality. Remarkably, additions of biothiols to Au(I)-Cys NSs have significantly enhanced their luminescence emission, and circular dichroism properties coupled with morphological modulations into nanoflowers, nanodendrites, or closely packed aggregates.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
School of Pharmaceutical Sciences, Liaoning University, 66 Chongshan Road, Shenyang 110036, Liaoning Province, P. R. China.
Clethodim is a chiral herbicide with two enantiomers. The herbicidal activity of (-)-clethodim is 1.3-2.
View Article and Find Full Text PDFACS Nano
January 2025
Department of Geriatric Oncology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 211166, P. R. China.
The protein corona effect refers to the phenomenon wherein nanomaterials in the bloodstream are coated by serum proteins, yet how protein coronated nanomaterials interact with blood vessels and its toxicity implications remain poorly understood. In this study, we investigated protein corona-related vessel toxicity by using an all-humanized assay integrating blood vessel organoids and patient-derived serum. Initially, we screened various nanomaterials to discern how parameters including size, morphology, hydrophobicity, surface charge, and chirality-dependent protein corona difference influence their uptake by vessel organoids.
View Article and Find Full Text PDFNon-invasive glucose monitoring is crucial for diabetes management. This study explores the use of photoacoustic (PA) signals based on optical rotation estimation at multiple depths for detection of glucose concentrations. Experiments were performed with glucose samples mixed in bovine serum albumin with different polarization incidences-vertical (V), 45° linear (P), and right circular (R) polarization.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!