Presented here is a novel automated method for determining the trace element composition of bulk thorium by inductively coupled plasma-optical emission spectroscopy (ICP-OES). ICP-OES is a universal approach for measuring the trace elemental impurities present in actinide-rich materials; however, due to the emission rich spectrum of the actinide, a separation from the trace elements is warranted for spectrochemical analysis. Here, AG MP-1 ion exchange resin was utilized for retention of the Th matrix, while allowing the trace element impurities to be separated prior to subsequent analysis using ICP-OES. After demonstrating the separation on traditional gravity-driven columns, the methodology was transitioned to an automated platform for comparison. This automated platform utilizes syringe-driven sample and solvent flow and can collect the trace element and thorium fractions in separate locations. While reducing the sample size (500 µL, 1.5 mg of Th), maintaining the overall separation efficiency (recoveries >95%), and illustrating the sample throughput ability (n = 10+), this automated methodology could be readily adopted to nuclear facilities in which the determination of trace elemental impurities in Th samples is warranted.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0003702820961390 | DOI Listing |
Microsc Res Tech
January 2025
Faculty of Dental Medicine, Grigore T. Popa University of Medicine and Pharmacy, Iasi, Romania.
One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.
View Article and Find Full Text PDFUltramicroscopy
January 2025
Mechanical Engineering, University of Michigan, USA.
The objective of this work was to explore the capabilities of a field emission gun scanning electron microscope (FEG-SEM) equipped with a transmission scanning electron detector (TSEM) and energy dispersive spectroscopy (EDS) to identify nanoscale chemical heterogeneities in a gas atomization reaction synthesis (GARS) steel sample. The results of this analysis were compared to the same study conducted with scanning transmission electron microscopy (STEM) with EDS mapping. TSEM-EDS was performed using the standard spectral analysis approach, i.
View Article and Find Full Text PDFMolecules
January 2025
Enviro Ecosmart SME, 189 Tecuci Street, 800552 Galati, Romania.
This study evaluates the effectiveness of Total Reflection X-ray Fluorescence for multi-element analysis in mussels, focusing on sensitivity, precision, and detection limits. Additionally, it offers a cross-regional comparison of elemental composition in mussels from aquaculture farms in Italy, Spain, and Chile. TXRF, using suspensions of mussel samples, proved effective in detecting minor and trace elements, with recovery rates over 80% for Fe, Cu, Zn, As, and Sr.
View Article and Find Full Text PDFLife (Basel)
December 2024
The Children's Memorial Health Institute, Department of Pediatrics, Nutrition and Metabolic Diseases, 04-730 Warsaw, Poland.
: We conducted a cross-sectional study to investigate whether children receiving long-term parenteral nutrition (LPN) are at risk of imbalances in selected trace elements. : Serum levels of manganese, zinc, copper, selenium, and iodine were measured in 83 children on LPN and compared with 121 healthy controls. Children with signs of infection or elevated C-reactive protein levels were excluded.
View Article and Find Full Text PDFToxics
December 2024
Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
This study investigated the elemental composition of , addressing the gap in comprehensive trace element profiling of this medicinal plant. The research aimed to determine the distribution of macronutrients, micronutrients, and beneficial and potentially toxic elements across different plant parts (seeds, leaves, stems, and roots). Using ICP-OES analysis, two digestion methods were employed to capture both complex and labile elements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!