Comparison of Speech Recognition and Localization Ability in Single-sided Deaf Patients Implanted With Different Cochlear Implant Electrode Array Designs.

Otol Neurotol

Department of Otorhinolaryngology-Head and Neck Surgery, Medical Centre-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.

Published: January 2021

Objective: Choice of electrode array (EA) design and differences in outcome are major concerns both to patients with single-sided deafness (SSD) and to surgeons before cochlear implant (CI) surgery. The present work investigates the effects of EA design on 1) insertion depths, and 2) audiological outcomes of SSD CI recipients.

Study Design: Retrospective study.

Setting: Tertiary academic center.

Patients: Forty patients with acquired SSD matched according to duration of deafness MAIN OUTCOME MEASURES:: Fourteen CI recipients were implanted with a perimodiolar electrode (cochlear perimodiolar [CPM]), 12 with a shorter lateral wall electrode (cochlear lateral wall [CLW]), and 14 with a longer lateral wall electrode array (medEl lateral wall [MLW]). Postoperative rotational tomography was evaluated to determine cochlear size and EA angle of insertion depth (AID). Binaural speech comprehension in noise (in three configuration presentations) and localization ability were assessed 12 months postoperatively with CI.

Results: AID was significantly deeper in MLW (mean 527.94 degrees) compared with the CPM (mean 366.35 degrees) and CLW groups (mean 367.01 degrees). No significant difference in AID was seen between the CPM and CLW groups (difference 0.66 degrees). Cochlear sizes revealed no significant differences between any groups. All three groups showed significant improvement in head shadow effect (difference on average CPM: 6.3 dB SPL, CLW 5 dB SPL, and MLW 4.05 dB SPL) and localization ability at 12 months postoperatively (difference on average CPM: 19.72 degrees, CLW: 24 degrees, and MLW: 12.9 degrees). No significant difference in the extent of audiological benefit was observed between any groups.

Conclusion: No effect on binaural benefit was apparent from the selection of the three EA designs in SSD CI recipients. Further studies focusing on subjective results, sound quality, and music perception depending on EA design in SSD CI recipients are needed.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000002864DOI Listing

Publication Analysis

Top Keywords

lateral wall
16
localization ability
12
electrode array
12
cochlear implant
8
electrode cochlear
8
wall electrode
8
months postoperatively
8
degrees clw
8
clw groups
8
degrees difference
8

Similar Publications

Internal herniation through the foramen of Winslow (FoW) is a rare, life-threatening diagnosis. We present a case of intestinal obstruction due to herniation of the ileum, cecum, appendix, and ascending colon through the FoW. We reduced the herniation using a small colotomy and preserved the entirety of the bowel.

View Article and Find Full Text PDF

Background: Local relapse has not been eradicated even in the era of total mesorectum excision. Although various approaches have been attempted, R0 resection remains the only potentially curative treatment. PATIENT AND METHODS: A 45-year-old woman with a history of laparoscopic abdominoperineal resection was diagnosed with pelvic recurrence 7 months ago.

View Article and Find Full Text PDF

Epithelioid haemangioendothelioma (EHE) is a rare vascular neoplasm characterised by proliferation of vascular endothelial and pre-endothelial cells. The prevalence is less than one in a million people. It is principally observed in the soft tissues of the extremities but can also occur in the bone, brain, liver, lung and lymph nodes.

View Article and Find Full Text PDF

Higher Aircraft Noise Exposure Is Linked to Worse Heart Structure and Function by Cardiovascular MRI.

J Am Coll Cardiol

December 2024

UCL MRC Unit for Lifelong Health and Ageing, University College London, London, United Kingdom; UCL Institute of Cardiovascular Science, University College London, London, United Kingdom; Centre for Inherited Heart Muscle Conditions, Cardiology Department, Royal Free Hospital, London, United Kingdom. Electronic address:

Background: Aircraft noise is a growing concern for communities living near airports.

Objectives: This study aimed to explore the impact of aircraft noise on heart structure and function.

Methods: Nighttime aircraft noise levels (L) and weighted 24-hour day-evening-night aircraft noise levels (L) were provided by the UK Civil Aviation Authority for 2011.

View Article and Find Full Text PDF

Narrow-gap arc welding is an efficient method that significantly enhances industrial production efficiency and reduces costs. This study investigates the application of low-alloy steel wire EG70-G in narrow-gap gas metal arc welding (GMAW) on thick plates. Experimental observations were made to examine the arc behavior, droplet transition behavior, and weld formation characteristics of double-wire welding under various process parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!