The potential aerosolised transmission of severe acute respiratory syndrome coronavirus-2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol-generating procedures to inform risk assessments. To address this evidence gap, we conducted real-time, high-resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l ) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l , n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l , n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l , n = 10) which was 15-fold greater than intubation (p = 0.0004) but 35-fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol-generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high-risk aerosol-generating procedure. These novel findings from real-time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol-generating procedure and the associated precautions for routine anaesthetic airway management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7675579PMC
http://dx.doi.org/10.1111/anae.15292DOI Listing

Publication Analysis

Top Keywords

tracheal intubation
12
aerosol generation
8
intubation extubation
8
airborne particles
8
average concentration
8
aerosol
5
quantitative evaluation
4
evaluation aerosol
4
generation tracheal
4
extubation potential
4

Similar Publications

Introduction: The aim of this study was to compare the histopathological findings in the resected tracheal ring of tracheotomized critically ill patients with or without severe SARS-CoV-2 infection.

Material And Methods: This is a prospective case-control study. The data collection period was between May 2020 and 2022.

View Article and Find Full Text PDF

"Thoracic anesthesia in patients with airborne disease".

Best Pract Res Clin Anaesthesiol

March 2024

Department of Surgery, Universitat de València, 46010 València, Spain; Ivano-Frankivsk National Medical University, 76018 Ivano-Frankivsk, Ukraine.

Health care workers are at risk of infection from aerosolization of respiratory secretions, droplet and contact spread. This has gained great importance after the COVID19 pandemic. Intra-operative aerosol-generating procedures are arguably unavoidable in the routine provision of thoracic anesthesia.

View Article and Find Full Text PDF

Acute respiratory distress syndrome (ARDS) secondary to chlorine gas inhalation is a rare yet critical condition that can lead to severe respiratory failure if not managed promptly. This case report presents a 43-year-old male who developed ARDS after accidental exposure to chlorine gas during pool maintenance. The patient's condition deteriorated rapidly, with symptoms progressing to acute pulmonary edema and severe hypoxemia, requiring immediate transfer to the intensive care unit (ICU).

View Article and Find Full Text PDF

Unlabelled: Children post-tracheoesophageal fistula (TEF) repair may present with chronic respiratory and gastrointestinal symptoms that can affect quality of life.

Objective: To identify factors associated with positive findings on triple endoscopy following neonatal TEF repair.

Study Design: Case series with retrospective review of patients.

View Article and Find Full Text PDF

Thermal burns of the larynx are uncommon but can lead to serious upper airway obstruction due to edema and bleeding, especially in children who may struggle to communicate their symptoms effectively. This report presents the case of a one-year-and-seven-month-old boy who developed stridor and respiratory distress after eating a heated potato, which ultimately required tracheal intubation. The initial evaluation suggested foreign body aspiration; however, laryngoscopy confirmed significant arytenoid swelling and airway narrowing due to thermal burns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?