Background: Superficial femoral artery lesion is one of the main causes for intermittent claudication or critical limb ischemia. Percutaneous transluminal angioplasty is one of the approved therapies for this medical entity. Anatomical factors should be considered in choosing the right approach and puncture.The purpose of this study is to discuss the anatomical, radiological, and technical factors which determine the preference of various approaches and to determine its safety, efficacy, and mid-term clinical and radiological outcome.

Methods: Retrospectively, data were collected from patients who underwent angioplasty to superficial femoral arteries for total occlusion from January 2015 and June 2018 in our center, we performed angioplasty to 59 occluded superficial femoral artery patients at our center. The ipsilateral femoral artery, ipsilateral popliteal artery, contralateral femoral artery, or upper limb approaches were used depending on the various anatomical factors determined by radiological imaging before the procedure.

Results: Acute success rate was 91.52%. There were no significant periprocedural complications. At the latest clinical follow-up of mean 25.8 months (10-51), a restenosis rate of 16.67% in infrainguinal arteries and 5.88% in suprainguinal arteries were noted.

Conclusions: Percutaneous transluminal angioplasty of superficial femoral artery is a proven, viable, safer, and effective option, with good mid-term clinical results and patency rates. Different approaches to be chosen depends on the anatomical and technical factors to get the best possible outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7507906PMC
http://dx.doi.org/10.4103/HEARTVIEWS.HEARTVIEWS_34_19DOI Listing

Publication Analysis

Top Keywords

femoral artery
24
superficial femoral
20
percutaneous transluminal
8
transluminal angioplasty
8
anatomical factors
8
technical factors
8
mid-term clinical
8
angioplasty superficial
8
femoral
7
artery
7

Similar Publications

Unveiling the uncommon: hypoplasia of external iliac artery-a case report and literature review.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000, P. R. China.

The absence or dysplasia of the iliac artery(IA) is an exceedingly rare condition, with limited cases documented in the literature. In this report, we present a case of hypoplasia of the right external iliac artery (EIA) in a 69-year-old male patient. The patient presented with right lower abdominal pain attributed to an aneurysm of the right internal iliac artery (IIA), yet notably, there was no evidence of lower limb ischemia at the time of consultation.

View Article and Find Full Text PDF

Complex wound closure scenarios necessitate the development of advanced wound dressings that can effectively address the challenges of filling irregularly shaped wounds and managing fatigue failures encountered in daily patient activities. To tackle these issues, we develop a multifunctional hydrogel from natural polysaccharides and polypeptides with injectability and self-healing properties for promoting full-time and multipurpose wound healing. Synthesized through dynamic Schiff base linkages between oxidized hyaluronic acid (OHA), ε-polylysine (ε-PL), and quaternized chitosan (QCS), the OHA/ε-PL/QCS hydrogel can gel rapidly within 50 s.

View Article and Find Full Text PDF

Purpose Of Review: This review assesses the outcomes of coronary interventions in patients with liver cirrhosis and coronary artery disease (CAD), focusing on the clinical challenges posed by cirrhosis-related hemodynamic and coagulopathic changes. It highlights essential considerations for managing these patients, who have an increased risk of adverse events during coronary procedures.

Recent Findings: Recent studies have shown that patients with liver cirrhosis undergoing PCI experience significantly higher mortality rates compared to non-cirrhotic patients, particularly in the context of STEMI and NSTEMI.

View Article and Find Full Text PDF

Emergency bleeding presents significant challenges such as high blood flow and rapid hemorrhaging. However, many existing hemostatic bandages face limitations, including the uncontrolled release of hemostatic agents, insufficient mechanical strength, poor adhesion, and complex manufacturing processes. To address these limitations, we developed a multifunctional hydrogel bandage for emergency hemostasis using a one-pot synthesis method.

View Article and Find Full Text PDF

Measurement of blood flow during exercise is crucial for understanding physiological responses and performance outcomes. However, traditional methods are often invasive, costly, or require substantial training, limiting widespread research in this area. This study introduces the innovative use of limb-affixed ultrasound probe holders for vascular imaging during exercise to overcome these challenges.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!