Background: Neck proprioception is critical in maintaining neuromuscular control in and around cervical joints. Kinesio™ tape may assist in rehabilitating joint position sense. The current study compares Kinesio™ tape's effects versus a placebo on proprioception in college athletes experiencing mechanical neck pain.
Methods: This study randomized sixty-six athletes with mechanical neck pain into a Kinesio™ tape group (n = 33, mean age = 22.73 years) or placebo group (n = 33, mean age = 23.15 years). The Kinesio™ tape group received standard Kinesio™ taping applications with appropriate tension, while the placebo group received taping applications without tension.
Outcome Measures: The study assessed cervical joint position errors with a cervical range-of-motion (CROM) device, pain intensity with a visual analog scale (VAS), and neck functional disability with a neck disability index (NDI). It tested joint position errors through cervical flexion, extension, rotation left, and rotation right. All the outcome measures were recorded at the baseline and twice more following 3 and 7 days of tape applications.
Results: Multivariate analysis of variance test demonstrated a significant reduction in joint position errors in flexion, extension and right rotation following 3 days and 7 days of tape application among the Kinesio™ tape group. There was a significant main effect of time (P < 0.05) for joint position errors in left rotation and VAS after 3 days (p > 0.05), NDI after 3 and 7 days (p > 0.05).
Conclusions: The Kinesio™ tape application after 3 and 7 days effectively decreased joint position errors and neck pain intensity in mechanical neck pain participants compared to placebo, while there was no difference between both groups in the NDI.
Trial Registration: ( CTRI/2011/07/001925 ). This study was retrospectively registered on the 27th July, 2011.
Level Of Evidence: IIB.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7533039 | PMC |
http://dx.doi.org/10.1186/s12891-020-03681-9 | DOI Listing |
Sci Rep
December 2024
Jiangsu Key Laboratory of Oil-Gas Storage and Transportation Technology, Changzhou University, Changzhou, 213164, Jiangsu, China.
Bend pipe is a common part of long distance pipeline. There is very important to study the flow law of hydrate particles in the bend pipe, and pipeline design will be optimized. In addition, the efficiency and safety of pipeline gas transmission will be improved.
View Article and Find Full Text PDFJ Am Acad Dermatol
December 2024
Mayo Clinic Dermatology, Scottsdale, Arizona 85259.
Appl Biosaf
December 2024
National Microbiology, Public Health Agency of Canada, Winnipeg, Canada.
Introduction: Positive pressure breathing-air-fed protective suits are used in biosafety level 4 (BSL-4) containment laboratories as personal protective equipment to protect workers from high-consequence pathogens. However, even with the use of primary containment devices, the exterior surfaces of these suits could potentially become contaminated with those pathogens and result in their inadvertent removal from containment. To address the risk of such pathogens escaping from containment via contaminated protective suits, these suits are decontaminated in a disinfectant chemical shower situated in an anteroom prior to exiting the BSL-4 laboratory.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Obstetrics and Gynecology rehabilitation, West China Second Hospital, Sichuan University, Huaxi Technology Building, 16 Linjiang Middle Road, Wuhou District, Chengdu, 610000, Sichuan, China.
Rectus abdominis diastasis (RAD) is a key factor in the rehabilitation of postpartum women. This study aimed to evaluate the clinical efficacy of Kinesio Taping (KT) in RAD treatment and abdominal changes. The medical records of women with RAD who received KT treatment at the hospital were reviewed.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Professor, Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey.
Statement Of Problem: Excess cement in implant-supported restorations can lead to peri-implant diseases, and its removal remains a clinical challenge. The optimum method of minimizing excess cement is unclear.
Purpose: The purpose of this in vitro study was to compare 3 cementation techniques and 3 cement types and measure excess cement.