The Relationship Between Vision and Comfort in Contact Lens Wear.

Eye Contact Lens

Brien Holden Vision Institute Limited (J.D., T.N., D.T., R.C.B.), Sydney, Australia ; and School of Optometry and Vision Sciences (T.N., D.T., R.C.B.), Sydney, Australia .

Published: May 2021

Objective: Understand relationship between vision and comfort in contact lens (CL) wear.

Methods: Retrospective analysis of five trials using similar protocols with nonpresbyopic (NP) myopes or presbyopic participants (Px) wearing various simultaneous-image designs (SM) and single-vision (SV) CL (NP only). Questionnaires (vision satisfaction, vision clarity: distance/intermediate/near, comfort) on 1 to 10 scale were administered 1 week after fitting. Vision/comfort relationship was analyzed using linear mixed model and presented as regression coefficient with 95% confidence intervals (CIs).

Results: Vision ratings correlated with comfort ratings, although this varied depending on type of vision rating and Px category. Vision satisfaction influenced comfort for the NP-SV group (slope: 0.8; 95% CI: 0.58-1.01, P≤0.001), but was significantly lower in the presbyopic group (slope: 0.38; 95% CI: 0.33-0.42; P≤0.001). Controlling for lens material obtained similar results. In the reverse relationship, comfort had a significant impact on vision satisfaction, although again at varying levels for each Px group. NP-SV demonstrated the weakest relationship (slope: 0.47; 95% CI: 0.35-0.59, P≤0.001) in comparison to NP-SM and P-SM groups.

Conclusion: Vision and comfort in CL wear are inter-related. Consideration of Px characteristics, visual stimulus, and CL comfort needs to be accounted for when assessing overall CL experience.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICL.0000000000000743DOI Listing

Publication Analysis

Top Keywords

vision comfort
12
vision satisfaction
12
relationship vision
8
comfort
8
comfort contact
8
contact lens
8
vision
8
group slope
8
relationship
5
lens wear
4

Similar Publications

Purpose: To evaluate the role of contact lenses (CLs) in visual rehabilitation following keratoplasty.

Methods: Four databases, including PubMed, Scopus, Web of Science, and Embase were systematically searched for studies published between January 2010 and July 2023. Visual outcomes, daily wearing duration, subjective comfort, rate and etiology of CL discontinuation, corneal endothelial cell density, central corneal thickness, and complications were extracted.

View Article and Find Full Text PDF

Introduction: Lotilaner ophthalmic solution (0.25%) is the first United States Food and Drug Administration (US FDA)-approved drug for treating Demodex blepharitis. In pivotal trials, it was found to be well tolerated and demonstrated a significant reduction in collarettes and mite density after a 6-week treatment regimen.

View Article and Find Full Text PDF

Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.

Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.

View Article and Find Full Text PDF

Retinitis pigmentosa (RP) is a heterogeneous group of inherited retinal diseases characterized by the progressive loss of photoreceptor function, visual impairment, and, ultimately, blindness. While gene therapy has emerged as a promising therapy, it is currently available only for the RPE65 gene mutation, leaving many patients without targeted genetic treatments. Non-surgical interventions may help in managing the progression of RP and improving patients' quality of life.

View Article and Find Full Text PDF

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!