A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

First-in-Human Study with Eight Patients Using an Absorbable Vena Cava Filter for the Prevention of Pulmonary Embolism. | LitMetric

Purpose: To prospectively evaluate the initial human experience with an absorbable vena cava filter designed for transient protection from pulmonary embolism (PE).

Materials And Methods: This was a prospective, single-arm, first-in-human study of 8 patients with elevated risk of venous thromboembolism (VTE). Seven absorbable IVC filters (made of polydioxanone that breaks down into HO and CO in 6 mo) were placed prophylactically before orthopedic (n = 5) and gynecologic (n = 2) surgeries, and 1 was placed in a case of deep vein thrombosis. Subjects underwent CT cavography and abdominal radiography before and 5, 11, and 36 weeks after filter placement to assess filter migration, embolization, perforation, and caval thrombosis and/or stenosis. Potential PE was assessed immediately before and 5 weeks after filter placement by pulmonary CT angiography.

Results: No symptomatic PE was reported throughout the study or detected at the planned 5-week follow-up. No filter migration was detected based on the fixed location of the radiopaque markers (attached to the stent section of the filter) relative to the vertebral bodies. No filter embolization or caval perforation was detected, and no caval stenosis was observed. Throughout the study, no filter-related adverse events were reported.

Conclusions: Implantation of an absorbable vena cava filter in a limited number of human subjects resulted in 100% clinical success. One planned deployment was aborted as a result of stenotic pelvic veins, resulting in 89% technical success. No PE or filter-related adverse events were observed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2020.07.021DOI Listing

Publication Analysis

Top Keywords

absorbable vena
12
vena cava
12
cava filter
12
filter
9
first-in-human study
8
study patients
8
pulmonary embolism
8
weeks filter
8
filter placement
8
filter migration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!