A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tissue microarray (TMA) use in post mortem neuropathology. | LitMetric

Tissue microarray (TMA) use in post mortem neuropathology.

J Neurosci Methods

Sheffield Institute for Translational Neuroscience, University of Sheffield, 385A Glossop Road, Sheffield, S10 2HQ, UK.

Published: January 2021

Background: Tissue microarrays (TMAs), where each block (and thus section) contains multiple tissue cores from multiple blocks potentially allow more efficient use of tissue, reagents and time in neuropathology.

New Method: The relationship between data from TMA cores and whole sections was investigated using 'virtual' TMA cores. This involved quantitative assessments of microglial pathology in white matter lesions and motor neuron disease, alongside qualitative TDP-43 inclusion status in motor neuron disease cases. Following this, a protocol was developed for TMA construction.

Results: For microglial pathology we found good concordance between virtual cores and whole sections for volume density using one 1.75 mm core (equivalent to a 2 mm core after accounting for peripheral tissue loss). More sophisticated microglial cell size and measures required two cores. Qualitative results of pTDP-43 pathology showed use of one 1.75 mm core gave a 100 % sensitivity and specificity within grey matter, and 88.3 % sensitivity and 100 % specificity within white matter. A method of producing the TMAs was suitable for immunohistochemistry both manually and by autostainer, with the minimal core loss from the microscope slide.

Comparison With Existing Methods: TMAs have been used infrequently in post mortem neuropathology research. However, we believe TMAs give comparable tissue assessment results and can be constructed, sectioned and stained with relative ease.

Conclusions: We found TMAs could be used to assess both quantitative (microglial pathology) and qualitative pathology (TDP-43 proteinopathy) with greatly reduced quantities of tissue, time and reagents. These could be used for further work to improve data acquisition efficiency.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2020.108963DOI Listing

Publication Analysis

Top Keywords

microglial pathology
12
post mortem
8
mortem neuropathology
8
tma cores
8
cores sections
8
white matter
8
motor neuron
8
neuron disease
8
175 mm core
8
tissue
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!