Background: One of the main indications for DRS is a diagnosis of obstructive uro-/nephropathy. In standard practice, this study includes the assessment of sequential scintigraphic images, renographic curves and such quantitative parameters as TMAX, T1/2 and split function of each kidney (SF). Due to the relative nature of SF and limitations of diagnostic capabilities of TMAX and T1/2, DRS was expanded to include new quantitative parameters describing kidney function in absolute values. This study aims to evaluate the usefulness of kidney efficiency index (KEi) - new, in-house developed parameter proportional to the average clearance function of the kidney.
Material And Methods: The study included 156 people aged 18-84 (average 51) years. The first group, from which normative values of new parameters were determined, consisted of 20 healthy volunteers. The second group consisted of 136 patients selected retrospectively, based on archived scintigraphic data. "Normalcy rate" (percentage of normal results among selected 62 patients with a low likelihood of obstructive uro-/nephropathy) was used to evaluate the reliability of KEi. A comparative differential analysis of obstructive uro-/nephropathy, based on standard and new DRS parameters, was performed on selected 74 patients (92 kidneys) with single functioning kidney or bilateral obstructive uropathy, where SF is unreliable.
Results: Normative values: KEi ≥ 8; Normalcy rate for KEi: 95%. In comparison with standard DRS evaluation, application of KEi changed the diagnosis in 1/3 of assessed kidneys (from uropathy to nephropathy in 27/92 kidneys and vice versa in 4 kidneys).
Conclusions: KEi enables reproducible, quantitative assessment of absolute kidney function without any modifications of the standard DRS protocol. Its values can be compared between independent studies (e.g. follow-up examinations). KEi corrected the diagnosis of obstructive uro-/nephropathy in cases of single functioning kidney or bilateral obstructive uropathy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5603/NMR.2020.0018 | DOI Listing |
J Clin Med
February 2021
Department of Quality Control and Radiation Protection, Medical University of Lodz, 92-216 Łódź, Poland.
This study evaluates the usefulness of parameters allowing assessment of renal function in absolute values in dynamic renal scintigraphy (DRS) with Tc-ethylenedicysteine (Tc-EC) uptake constant (K), mean transit time (MTT), and parenchymal transit time (PTT) in the diagnosis of obstructive uro/nephropathy. The study included 226 people: 20 healthy volunteers, for whom normative values of assessed parameters were determined, and 206 patients. Reproducibility of results obtained by two independent operators, specificity, correlation with estimated GFR (eGFR), and Cohen's kappa were used to evaluate reliability of assessed parameters.
View Article and Find Full Text PDFNucl Med Rev Cent East Eur
July 2021
Department of Nuclear Medicine, Medical University of Łódź, ul. Czechosłowacka 8/10, 92-216 Łódź, Poland.
Background: One of the main indications for DRS is a diagnosis of obstructive uro-/nephropathy. In standard practice, this study includes the assessment of sequential scintigraphic images, renographic curves and such quantitative parameters as TMAX, T1/2 and split function of each kidney (SF). Due to the relative nature of SF and limitations of diagnostic capabilities of TMAX and T1/2, DRS was expanded to include new quantitative parameters describing kidney function in absolute values.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!