A single sheet of nickel-titanium (NiTi) shape memory alloy (SMA) was introduced within an IM7/8552 polymer matrix composite (PMC) panel in conjunction with multiple thin film adhesives to promote the interfacial bond strength between the SMA and PMC. End notched flexure (ENF) testing was performed in accordance to ASTM D7905 method for evaluation of mode II interlaminar fracture toughness (G) of unidirectional fiber-reinforced polymer matrix composites. Acoustic emissions (AE) were monitored during testing with two acoustic sensors attached to the specimens. The composite panels examined using scanning electron microscopy techniques after part failure. G values for the control composite samples were found to be higher than those of samples with embedded SMA sheets. The presence of adhesives bonded to SMA sheets further diminished the G values. AE values revealed poor bonding of the panels, with little to no signals during testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7526532PMC
http://dx.doi.org/10.1016/j.mechmat.2019.01.002DOI Listing

Publication Analysis

Top Keywords

thin film
8
film adhesives
8
mode interlaminar
8
interlaminar fracture
8
fracture toughness
8
shape memory
8
memory alloy
8
polymer matrix
8
sma sheets
8
adhesives mode
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?