A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Role of Ultrahigh Frequency Ultrasound in Evaluating Experimental Flaps. | LitMetric

Background:  Experimental flap follow-up needs faster, safer, and less invasive techniques that can be easily correlated to clinical procedures. For this reason, we aimed to test the role of ultrahigh frequency ultrasound in follow-up of flap viability. Further on, we aimed to analyze if the chimeric groin flap can be mobilized in a sandwiched position without affecting its vascular supply by twisting its pedicle.

Methods:  A total of 12 male Wistar rats, split into three groups, were used. Group A ( = 4) had the chimeric groin flap repositioned in a sandwich position on the anterior abdominal wall and underwent ultrahigh frequency ultrasound follow-up at days 10 and 14. Group B ( = 4) also had the flaps sandwiched, however, at day 14 the vascularity of flaps was proven by infusion of nontargeted ultrasound contrast agents, after which flaps were sent for histological analysis. Group C (C1  = 2, C2  = 2) was the control group. In C1 the chimeric groin flap was harvested and sent for histology on day 0, acting as a histological benchmark of flap viability, and in C2 the chimeric groin flap was re-sutured in its anatomical position and after 14 days, flaps were harvested and sent for histological analysis, acting as a direct control for Group B.

Results:  Ultrasound showed constant vascular flow in both adipose and skin flaps in the sandwiched position. Microbubble study showed diffuse perfusion within flaps. Ultrasound measurements of flow velocity, flap volume, and percentage of vascularity showed a decrease in flap volume and increase in vascularity over 14 days. Histology showed similar viability in both groups.

Conclusion:  Ultrahigh frequency ultrasound may be a valuable tool for postoperative flap assessment, while the chimeric flap can be moved freely in a sandwich position making it suitable for adding tissue substitutes within its components.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1718392DOI Listing

Publication Analysis

Top Keywords

frequency ultrasound
16
chimeric groin
16
groin flap
16
ultrahigh frequency
12
flap
11
role ultrahigh
8
ultrasound follow-up
8
flap viability
8
sandwiched position
8
group  = 4
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!