This Letter discusses the generation of 3D-printed micro-optics to obtain the desired beam profile from a multimode vertical-cavity surface-emitting laser (VCSEL) with a significantly reduced divergence angle via the usage of high-resolution two-photon polymerization. Due to the low cost and compact packaging, the VCSEL array is a novel light source for structured-light projection. Particularly for long-distance 3D sensing applications, a greatly reduced divergence angle ensures that a good signal with a sufficiently large number of photons can be recorded, and the projected illumination spots do not overlap. Therefore, exact laser beam characterization and appropriate physical modeling are required in accurate production of an optimal collimator lens. Furthermore, elliptical beam profiles with different orientations can solve the correspondence problem and improve the post-processing speed and robustness in structured light. To generate this special type of beam profile and verify the optical design process, this Letter describes thoroughly the optical prototyping process starting from the beam characterization, the optical design to the production of the two-photon polymerized optics, and its validation. The test of the beam profile and divergence confirm a good match of the produced optics with the physical optical simulation in Zemax. The collimator transforms the input laser beam divergence angle of 324 mrad to an output angle of 20 mrad only.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.401160DOI Listing

Publication Analysis

Top Keywords

beam profile
12
divergence angle
12
reduced divergence
8
laser beam
8
beam characterization
8
optical design
8
beam
7
generation high-resolution
4
high-resolution 3d-printed
4
3d-printed freeform
4

Similar Publications

Conventional approaches for the structural health monitoring of infrastructures often rely on physical sensors or targets attached to structural members, which require considerable preparation, maintenance, and operational effort, including continuous on-site adjustments. This paper presents an image-driven hybrid structural analysis technique that combines digital image processing (DIP) and regression analysis with a continuum point cloud method (CPCM) built on a particle-based strong formulation. Polynomial regressions capture the boundary shape change due to the structural loading and precisely identify the edge and corner coordinates of the deformed structure.

View Article and Find Full Text PDF

Purpose: High dose rate (HDR) brachytherapy is increasingly adopted for dose escalation in prostate cancer treatment. We report the clinical efficacy and toxicity of HDR prostate brachytherapy combined with external beam radiotherapy (EBRT) and evaluate the predictability of the biochemical definition of cure of 4-year PSA ≤0.2 ng/mL for failure free survival (FFS).

View Article and Find Full Text PDF

Proton minibeam radiation therapy (pMBRT) dose profile is characterized by highly heterogeneous dose in the plane perpendicular to the beam direction and rapidly changing depth dose profiles. Typically, dose measurements are benchmarked against in-house Monte Carlo simulation tools. It is essential to have a treatment planning system (TPS) that can accurately predict pMBRT doses in tissue and be available via commercial platform for preclinical and clinical use.

View Article and Find Full Text PDF

Background: The electronic compensation (ECOMP) technique for breast radiation therapy provides excellent dose conformity and homogeneity. However, the manual fluence painting process presents a challenge for efficient clinical operation.

Purpose: To facilitate the clinical treatment planning automation of breast radiation therapy, we utilized reinforcement learning (RL) to develop an auto-planning tool that iteratively edits the fluence maps under the guidance of clinically relevant objectives.

View Article and Find Full Text PDF

This experimental phantom study investigates current standard of care protocols in cone beam computed tomography (CBCT), energy-integrating-detector (EID) CT, and photon-counting-detector (PCD) CT regarding their potential in delineation of dental root canals. Artificial accessory canals (diameters: 1000, 600, 400, 300 and 200 μm) were drilled into three bovine teeth mounted on a bovine rib as a jaw substitute. The phantom was scanned in two dental CBCTs, two EID-CTs and a PCD-CT using standard clinical protocols.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?