Independent treatment planning system (TPS) check with Mobius3D software, log files based quality assurance (QA) with MobiusFX, and phantom measurement-based QA with ArcCHECK were performed and cross verified for head-and-neck (17 patients), chest (16 patients), and abdominal (19 patients) cancer patients who underwent volumetric modulated arc therapy (VMAT). Dosimetric differences and percentage gamma passing rates (%GPs) were evaluated and compared for this cross verification. For the dosimetric differences in planning target volume (PTV) coverage, there was no significant difference among TPS vs. Mobius3D, TPS vs. MobiusFX, and TPS vs. ArcCHECK. For the dosimetric differences in organs at risks (OARs), the number of metrics with an average dosimetric differences higher than ±3% for TPS vs Mobius3D, TPS vs MobiusFX, and TPS vs ArcCHECK were 1, 1, 7; 2, 1, 4; 1, 1, 5 for the patients with head-and-neck, abdomen, and chest cancer, respectively. The %GPs of global gamma indices for Mobius3D and MobiousFX were above 97%, while it ranged from 92% to 96% for ArcCHECK. The %GPs of individual volume-based gamma indices were around 98% for Mobius3D and MobiousFX, except for γPTV for chest and abdominal cancer (88.9% to 92%); while it ranged from 86% to 99% for ArcCHECK. In conclusion, some differences in dosimetric metrics and gamma passing rates were observed with ArcCHECK measurement-based QA in comparison with independent dosecheck and log files based QA. Care must be taken when considering replacing phantom measurement-based IMRT/VMAT QA.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7700942 | PMC |
http://dx.doi.org/10.1002/acm2.13036 | DOI Listing |
Radiat Oncol
January 2025
Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200025, P.R. China.
Aim: To characterize the differences of dynamic changes for absolute lymphocyte count (ALC) among esophageal squamous cell carcinoma (ESCC) patients treated with neoadjuvant chemoradiotherapy (nCRT) with or without pembrolizumab, as well as to investigate the clinical and lymphocyte-related organs dosimetric parameters that would impact ALC nadir during nCRT.
Materials And Methods: A total of 216 ESCC patients who received nCRT (with pembrolizumab 144; without pembrolizumab: 72) were identified from a prospective cohort. Weekly and 1-month post-nCRT ALC were identified.
Radiother Oncol
January 2025
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA; Medical Artificial Intelligence and Automation Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX, USA. Electronic address:
Background And Purpose: Daily online adaptive radiotherapy (DART) increases treatment accuracy by crafting daily customized plans that adjust to the patient's daily setup and anatomy. The routine application of DART is limited by its resource-intensive processes. This study proposes a novel DART strategy for head and neck squamous cell carcinoma (HNSCC), automizing the process by propagating physician-edited treatment contours for each fraction.
View Article and Find Full Text PDFRadiography (Lond)
January 2025
School of Nursing, The Hong Kong Polytechnic University, Hong Kong. Electronic address:
Introduction: Deep inspiration breath hold technique has shown promise in reducing cardiac toxicity and improving patient outcomes. However, there is a lack of consensus regarding the implementation of abdominal breath hold technique and its impact on cardiac dose. This systematic review and meta-analysis aim to provide insights into the comparative effectiveness of abdominal and thoracic breath hold in mitigating cardiac toxicity during radiation therapy for left-sided breast cancer.
View Article and Find Full Text PDFPhys Med
January 2025
Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, 71003 Iraklion, Crete, Greece.
Purpose: To investigate the performance of a machine learning-based segmentation method for treatment planning of gastric cancer.
Materials And Methods: Eighteen patients planned to be irradiated for gastric cancer were studied. The target and the surrounding organs-at-risk (OARs) were manually delineated on CT scans.
Clin Transl Radiat Oncol
January 2025
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Dr. Molewaterplein 40, 3015 GD Rotterdam, the Netherlands.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!