Percutaneous image-guided double oblique anterior approach to the acetabulum for cementoplasty.

Clin Radiol

Department of Interventional Radiology, Nouvel Hôpital Civil, 1, Place de L'Hôpital, 67096 Cedex, Strasbourg, France.

Published: December 2020

Aim: To report the technique of percutaneous double oblique anterior access to the acetabulum and evaluate its feasibility and safety.

Materials And Methods: Pelvic computed tomography (CT) examinations of 60 patients (30 men and 30 women; mean age 62.6±13.2 years) were retrieved randomly from the picture archiving and communication system (PACS). A virtual intraosseous trajectory was defined on both sides on the axial CT images with the entry point marked 1 cm above the anterosuperior iliac spine and the endpoint defined just above the level of the ischial spine at the midpoint of the posterior acetabulum. Patient age, sagittal oblique angulation, axial oblique angulation, length of intraosseous trajectory, distance from the hip joint, thickness of the iliac bone cortex, and intervening structure(s) between the skin and the bone entry points were recorded.

Results: The mean sagittal and axial oblique angulations were 34.2±4.5° and 31.5±6.7°, respectively, and mean length of the intraosseous trajectory was 11.8±0.9 cm. The axial oblique angle and length of the intraosseous trajectory were significantly lower in the female than the male population (p<0.05). None of the virtual trajectories traversed the hip joint. In 112/120 trajectories (93.3%), there were no cortical breaches in the iliac bones. In eight trajectories in four patients, the virtual trajectory crossed either the medial iliac cortex (4/120; 3.3%) or the medial iliac cortex and the iliacus muscle (4/120; 3.3%).

Conclusion: The anterosuperior iliac and ischial spines can be used safely and reliably as landmarks to perform the double oblique anterior approach.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.crad.2020.09.001DOI Listing

Publication Analysis

Top Keywords

intraosseous trajectory
16
axial oblique
12
length intraosseous
12
double oblique
8
oblique anterior
8
oblique angulation
8
oblique
6
percutaneous image-guided
4
image-guided double
4
anterior approach
4

Similar Publications

Simplifying the Orientation of S1 Iliosacral Screws for Placement in the Dysmorphic Sacrum.

J Bone Joint Surg Am

September 2024

Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, Hebei Province, People's Republic of China.

Background: Determining the proper iliosacral screw orientation in a dysmorphic S1 sacral segment using a C-arm is difficult, and pelvic computed tomography (CT) is often necessary for the preoperative planning. On the preoperative pelvic axial CT section, the intended screw trajectory can be delineated intraosseously along the axis of the oblique osseous corridor. An inherently accurate orientation would be determined by 2 factors: (1) the trajectory is in the pelvic transverse plane, and (2) it is oriented relative to the coronal plane at a patient-specific angle, which should be measured preoperatively.

View Article and Find Full Text PDF

Background: A growing body of clinical evidence has demonstrated that intraosseous minimally invasive basivertebral nerve (BVN) ablation results in significant and durable improvements in vertebrogenic back pain. Thus, it is important to develop, refine and validate new and additional devices to accomplish this procedure.

Methods: Using reconstructions of 31 patient computed tomography (CT) scans of the lumbosacral spine (L1-S1), the primary objective was to simulate the intravertebral placement of a novel multitined expandable electrode in bipolar configuration at the targeted ablation site and determine if the proper trajectories could be achieved in order for the device tips to be in the correct position for lesion formation at the BVN plexus.

View Article and Find Full Text PDF
Article Synopsis
  • The "Tripod Technique" is a surgical method for treating metastatic periacetabular lesions, showing good outcomes but requiring skilled execution due to potential complications.
  • Researchers developed a custom guiding frame using preoperative CT scans and advanced technology like a convolutional neural network to optimize screw placement.
  • In a study with 12 patients, the guiding frame significantly reduced surgery time and improved pain management and functional status post-operation, indicating the technique's effectiveness.
View Article and Find Full Text PDF

BACKGROUND The proper installation for pedicle screws by the traditional method of surgeons dependent on experience is not guaranteed, and educational solutions have progressed from chalkboards to electronic teaching platforms. We designed a case of 3-dimensional printing drill guide template as a surgical application, which can accurately navigate implantation of pedicle screws, and assessed its effect for simulative training. MATERIAL AND METHODS We randomly selected a set of computed tomography data for spondylolisthesis.

View Article and Find Full Text PDF

Purpose: To compare the Atlas (C1) lateral mass screw placement between screw trajectories of 0° and 15° medial angulation while using the intersection between lateral mass and inferomedial edge of the posterior arch.

Methods: Forty-eight Atlas lateral masses were prepared and divided into 2 groups: Group 1; screws inserted at 3 mm lateral to the reference point with screw trajectory of 0° angulation(N = 24) and Group 2; those inserted with screw trajectory of 15° medial angulation(N = 24). We evaluated the atlas anatomy, screw purchase and the presence of any breaches using CT scan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!