Detection of primary angleclosure suspect with different mechanisms of angle closure using multivariate prediction models.

Acta Ophthalmol

Beijing Tongren Eye Center, Beijing Key Laboratory of Ophthalmology and Visual Science, Beijing Tongren Hospital, Capital Medical University, Beijing, China.

Published: June 2021

AI Article Synopsis

  • A study evaluated a multivariate prediction model for identifying primary angle-closure suspects (PACS) using various anterior segment imaging techniques, achieving a strong detection accuracy with an AUC of 0.844.
  • The research analyzed data from 796 participants and used logistic regression, Naïve Bayes, and neural networks to assess prediction performance across different angle closure mechanisms.
  • Results indicated that the model performed best for PACS caused by pupillary block, with AUC values above 0.9, highlighting its potential for effective screening in clinical settings.

Article Abstract

Purpose: We had found that a multivariate prediction model used for the detection of primary angle-closure suspects (PACS) by combining multiple static and dynamic anterior segment optical coherence tomography (ASOCT) parameters had an area under the receiver operating characteristic curve (AUC) of 0.844. We undertook this study to evaluate this method in screening of PACS with different dominant mechanisms of angle closure (AC).

Methods: The right eyes of subjects aged ≥40 years who participated in the 5-year follow-up of the Handan Eye Study and had undergone gonioscopy and ASOCT examinations under light and dark conditions were included. All ASOCT images were analysed by the Zhongshan Angle Assessment Program. The dominant AC mechanism in each eye was determined to be pupillary block (PB), plateau iris configuration (PIC) or thick peripheral iris roll (TPIR). Backward logistic regression (LR) was used for inclusion of variables in the prediction models. LR, Naïve Bayes' classification (NBC) and neural network (NN) were evaluated and compared using the AUC.

Results: Data from 796 subjects (413 PACS and 383 normal eyes) were analysed. The AUCs of LR, NBC and NN in the PB group were 0.920, 0.918 and 0.917. The AUCs of LR, NBC and NN in the PIC group were 0.715, 0.708 and 0.707. The AUCs of LR, NBC and NN in TPIR group were 0.867, 0.833 and 0.886.

Conclusions: Prediction models showed the best performance for detection of PACS with PB mechanism for AC and have potential for screening of PACS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8359395PMC
http://dx.doi.org/10.1111/aos.14634DOI Listing

Publication Analysis

Top Keywords

prediction models
12
aucs nbc
12
detection primary
8
mechanisms angle
8
angle closure
8
multivariate prediction
8
screening pacs
8
pacs
5
primary angleclosure
4
angleclosure suspect
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!