A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Thermal imaging dataset from composite material academic samples inspected by pulsed thermography. | LitMetric

This paper presents a thermal imaging dataset from composite material samples (carbon and glass fiber reinforced plastic) that were inspected by pulsed thermography with the goal of detecting and characterizing subsurface defective zones (Teflon inserts representing delaminations between plies). The pulsed thermography experiment was applied to 6 academic plates (inspected from both sides) all having the dimensions of 300 mm x 300 mm x 2 mm and same distribution of defects but made of different materials: three plates on carbon fiber-reinforced plastic (CFRP) and three plates made on glass fiber reinforced plastic (GFRP) specimens with three different geometries: planar, curved and trapezoidal. Each plate contains 25 inserts having length/depth ratios between 1.7 and 75. Two FX60 BALCAR photographic flashes (6.2 kJ per flash) were used to generate the heat pulse (2 ms duration), an X6900 FLIR infrared camera using ResearchIR software to record the thermal images and a custom-built software/control unit to synchronize data recording with pulse generation. Finally, the dataset proposed consists of 12 sequences of approximately 2000 images of 512 × 512 pixels each.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7508994PMC
http://dx.doi.org/10.1016/j.dib.2020.106313DOI Listing

Publication Analysis

Top Keywords

pulsed thermography
12
thermal imaging
8
imaging dataset
8
dataset composite
8
composite material
8
inspected pulsed
8
glass fiber
8
fiber reinforced
8
reinforced plastic
8
three plates
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!