AI Article Synopsis

  • The study evaluated the use of a new double-layer ChenValve prosthesis for transcatheter aortic valve implantation (TAVI) in patients with noncalcified aortic valves, which was previously a contraindication for TAVI.
  • The ChenValve consists of a self-expanding Nitinol ring and a balloon-expandable stent, successfully implanted in 10 goats with proper positioning and no significant complications observed.
  • The findings suggest that this approach enhances the safety and repeatability of TAVI in treating noncalcified aortic valves, offering a potential alternative for patients who were not eligible for traditional procedures.

Article Abstract

Background: In this study, we sought to evaluate the feasibility of improved transcatheter aortic valve implantation (TAVI) in noncalcified aortic valve by using the novel concept of double-layer ChenValve prosthesis. TAVI was initially considered as an alternative treatment for high-risk patients with aortic stenosis. However, non noncalcified aortic valve disease was considered as a contraindication to TAVI.

Methods: ChenValve prosthesis, which consisted of a self-expanding Nitinol ring, a balloon-expandable cobalt-chromium alloy stent and a biological valve, was implanted at the desired position under fluoroscopic guidance in a transapical approach through a 20F sheath in 10 goats. Aortic angiography was performed to measure the diameter of the aotic annulus and assess the performance of the artificial valve. The ultrasound was used to evaluate the regurgitation or paravalvular leakage and trans-prosthetic vascular flow velocity postoperatively. The aortogram and transthoracic echocardiography were applied to observe whether the valve stent was implanted at the desired position.

Results: ChenValve prosthesis was successfully transppical implanted in all animals. The aortogram and transthoracic echocardiography performed immediately after implantation revealed that the valve stent was implanted at the desired position. There was no significant paravalvular leakage, obstruction of coronary artery ostia, stent malpositioning or dislodgement occurred.

Conclusions: This preliminary trial with the novel double-layer ChenValve prosthesis demonstrated the feasibility of improved TAVI in noncalcified aortic valve. The mechanism of Nitinol ring-guided locating the aortic sinus enables us to anatomically correct position the artifact valve. This improved strategy seems to make the TAVI process more safe and repeatable in noncalcified aortic valve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7525934PMC
http://dx.doi.org/10.1186/s13019-020-01327-4DOI Listing

Publication Analysis

Top Keywords

aortic valve
24
noncalcified aortic
16
chenvalve prosthesis
16
implanted desired
12
valve
11
aortic
10
improved transcatheter
8
transcatheter aortic
8
valve implantation
8
feasibility improved
8

Similar Publications

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF

Revisiting the Neuropsychological and Clinical Profile of Mosaic Turner Syndrome With a Ring X Chromosome.

Am J Med Genet C Semin Med Genet

January 2025

Medical Genetics, Department of Pediatrics, Mass General for Children, Boston, Massachusetts, USA.

Determining karyotype-phenotype correlations for individuals with Turner syndrome ("TS individuals") is a longstanding research endeavor. The limited literature on Turner syndrome (TS) with a ring X chromosome hinders counseling about the neuropsychological and clinical features. To further characterize these phenotypes, we compared 27 TS individuals with 46,X,r(X)/45,X ("ring X") to 50 non-mosaic 45,X, and 27 mosaic 45,X/46,XX ("mosaic 45,X") individuals.

View Article and Find Full Text PDF

Background: The human microbiome is crucial in regulating intestinal and systemic functions. While its role in cardiovascular disease is better understood, the link between intestinal microbiota and valvular heart diseases (VHD) remains largely unexplored.

Methods: Peer-reviewed studies on human, animal or cell models analysing gut microbiota profiles published up to April 2024 were included.

View Article and Find Full Text PDF

Severe mitral regurgitation (MR) following surgical repair of the mitral valve poses a significant clinical challenge. Patients who have undergone surgery are typically at high risk for a second operation. This report details the case of a 54-year-old male who underwent aortic valve replacement and mitral valve repair using a 34-ring, 14 years prior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!