Aims: Eight-plates are used to correct varus-valgus deformity (VVD) or limb-length discrepancy (LLD) in children and adolescents. It was reported that these implants might create a bony deformity within the knee joint by change of the roof angle (RA) after epiphysiodesis of the proximal tibia following a radiological assessment limited to anteroposterior (AP) radiographs. The aim of this study was to analyze the RA, complemented with lateral knee radiographs, with focus on the tibial slope (TS) and the degree of deformity correction.
Methods: A retrospective, single-centre study was conducted. The treatment group (n = 64 knees in 44 patients) was subclassified according to the implant location in two groups: 1) medial hemiepiphysiodesis; and 2) lateral hemiepiphysiodesis. A third control group consisted of 25 untreated knees. The limb axes and RA were measured on long standing AP leg radiographs. Lateral radiographs of 40 knees were available for TS analysis. The mean age of the patients was 10.6 years (4 to 15) in the treatment group and 8.4 years (4 to 14) in the control group. Implants were removed after a mean 1.2 years (0.5 to 3).
Results: No significant differences in RA (p = 0.174) and TS (p = 0.787) were observed. The limb axes were significantly corrected in patients with VVD (p < 0.001). The change in tibial slope (∆TS) did not correlate ( = -0.026; p = 0.885) to the plate's position on the physis when assessed by lateral radiographs.
Conclusion: We were not able to confirm the reported change in the bony morphology of the proximal tibia on AP radiographs in our patient population. In addition, no significant change in TS was detected on the lateral radiographs. A significant correction of the VVD in the lower limb axes was evident. Position of the implant did not correlate with TS change. Therefore, eight-plate epiphysiodesis is a safe and effective procedure for correcting VVD in children without disturbing the knee joint morphology. Cite this article: 2020;102-B(10):1412-1418.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1302/0301-620X.102B10.BJJ-2020-0473.R1 | DOI Listing |
J Small Anim Pract
December 2024
The Queen Mother Hospital for Animals, Royal Veterinary College, Hatfield, UK.
Construct failure is a rare complication of tibial cranial closing wedge ostectomy for the management of cranial cruciate ligament disease. Construct failure can present significant challenges for reconstruction. This case report describes three dogs with construct failure which were successfully revised by the repurposing of an inverted femoral supracondylar femoral plate as part of the revision.
View Article and Find Full Text PDFJBJS Essent Surg Tech
December 2024
Department of Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, Connecticut.
Background: For complete disruption of the posterolateral corner (PLC) structures, operative treatment is most commonly advocated, as nonoperative treatment has higher rates of persistent lateral laxity and posttraumatic arthritis. Some studies have shown that acute direct repair results in revision rates upwards of 37% to 40% compared with 6% to 9% for initial reconstruction. In a recent study assessing the outcomes of acute repair of PLC avulsion injuries with 2 to 7 years of follow-up, patients with adequate tissue were shown to have a much lower failure rate than previously documented.
View Article and Find Full Text PDFJt Dis Relat Surg
January 2025
Ankara Şehir Hastanesi, Ortopedi ve Travmatoloji Kliniği, 06800 Çankaya, Ankara, Türkiye.
Objectives: This study aimed to radiologically evaluate the possible relationship between the body mass index (BMI) and recurrence of varus deformity during the mid-term follow-up of patients treated for medial gonarthrosis.
Patients And Methods: Fifty-six patients (11 males, 45 females; mean age: 53.8±7.
J Pediatr Orthop B
December 2024
Department of Paediatric Orthopaedics, Chacha Nehru Bal Chikitsalaya, Delhi, India.
We studied the correlation between changes in the interscrew angle (screw divergence) and the correction achieved with tension band plates applied for valgus deformities of the knee region. Twenty-eight children with 68 operated physes were included in this retrospective review. The interscrew angle and screw trajectory angle were measured in the initial and follow-up radiographs.
View Article and Find Full Text PDFInt J Med Robot
December 2024
Tsiridis Orthopaedic Institute, ICAROS Clinic, Thessaloniki, Greece.
Background: We investigated the accuracy of targeted resection thickness in patients undergoing primary Total Knee Arthroplasty (TKA) using the ROSA robotic system.
Methods: Calliper measurements of the distal femur (DF), proximal tibia (PT), and posterior condyles (PC) were taken in 44 patients from June 2023 to January 2024.
Results: Planned and actual resection depth difference was 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!