The use of sonographic myometrial thickness measurements for the prediction of time from induction of labor to delivery.

Arch Gynecol Obstet

Department of Obstetrics and Gynecology, Soroka University Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, POB 151, 84101, Beer-Sheva, Israel.

Published: April 2021

Background: Several attempts have been made to find tools for the prediction of successful induction of labor. Sonographic myometrial thickness has not yet been investigated regarding its use as a clinical tool for the course of labor induction.

Objective: To evaluate the role of sonographic measurement of myometrial thickness in the prediction of the time interval to successful vaginal delivery after induction of labor.

Study Design: A prospective study was conducted including term singleton pregnancies with a vertex presentation designated for balloon induction at 38-42 weeks gestation. Prior to induction, abdominal sonographic myometrial thickness was assessed at five locations: lower uterine segment (above and below the reflection of the urinary bladder), mid-anterior wall, fundus and posterior uterine wall. Induction of labor was then carried out with a trans-cervical Foley catheter that was substituted with intravenous oxytocin after balloon expulsion. The parameters assessed were successful induction of labor resulting in a vaginal delivery and the time interval from balloon insertion to balloon expulsion, the time interval from initiation of oxytocin administration to delivery and the total time from balloon insertion to delivery.

Results: Fifty-two women were recruited to the study. Indications for labor induction were: post-date pregnancy (48.1%), gestational diabetes mellitus (19.2%), oligohydramnios (11.5%), gestational hypertensive disorders (5.8%) and other indications (15.4%). Vaginal delivery was achieved in 46 patients (88.5%). A statistically significant correlation was found between fundal and posterior uterine wall myometrial thickness and time from induction to balloon expulsion (r = 0.36, p = 0.03; r = - 0.35, p = 0.05, respectively). This correlation remained significant in a multivariate logistic regression model controlling for confounders. A correlation between myometrial thickness and the total time from induction to delivery was not statistically significant.

Conclusion: Myometrial fundal and posterior uterine wall thickness in women undergoing labor induction with a balloon catheter was found to be correlated with the interval from balloon insertion to expulsion. Our findings support further investigations into the use of sonographic myometrial thickness as part of the assessment prior to induction of labor.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00404-020-05811-zDOI Listing

Publication Analysis

Top Keywords

myometrial thickness
28
induction labor
20
sonographic myometrial
16
induction
12
time induction
12
time interval
12
vaginal delivery
12
posterior uterine
12
uterine wall
12
balloon expulsion
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!