Background: The accuracy of robot-assisted pedicle screw implantation is a safe and effective method in lumbar surgery, but it still remains controversial in lumbar revision surgery. This study evaluated the clinical safety and accuracy of robot-assisted versus freehand pedicle screw implantation in lumbar revision surgery.
Methods: This was a retrospective study. From January 2018 to December 2019, 81 patients underwent posterior lumbar revision surgery in our hospital. Among them, 39 patients underwent revision surgery performed with robot-assisted pedicle screw implantation (Renaissance robotic system), whereas the remaining 42 patients underwent traditional freehand pedicle screw implantation. All patients underwent magnetic resonance imaging (MRI), computed tomography (CT), and X-ray before revision surgery. The sex, age, body mass index, bone mineral density, operative time, blood loss, operative segments, intra-operative fluoroscopy time, and complications were compared between the two groups. The accuracy of pedicle screw implantation was measured on CT scans based on Gertzbein Robbins grading, and the invasion of superior level facet joint was evaluated by Babu's method.
Results: There was no statistical difference about the baseline between the two groups (P > 0.05). Although there were no significant differences in operative time and complications between the two groups (P > 0.05), the robot-assisted group had significantly less intra-operative blood loss and shorter intra-operative fluoroscopy times than the freehand group (P < 0.05). In the robot-assisted group, a total of 267 screws were inserted, which were marked as grade A in 250, grade B in 13, grade C in four, and no grade D or E in any screw. In terms of invasion of superior level facet joint, a total of 78 screws were inserted in the robot-assisted group, which were marked as grade 0 in 73, grade 1 in four, grade 2 in one, and grade 3 in zero. By comparison, 288 screws were placed in total in the freehand group, which were rated as grade A in 251, grade B in 28, grade C in eight, grade D in one, and no grade E in any screw. A total of 82 superior level facet joint screws were inserted in freehand group, which were marked as grade 0 in 62, grade one in 18, grade 2 in two, and grade 3 in zero. The robot-assisted technique was statistically superior to the freehand method in the accuracy of screw placement (P < 0.05).
Conclusion: Compared with freehand screw implantation, in lumbar revision surgery, the Renaissance robot had higher accuracy and safety of pedicle screw implantation, fewer superior level facet joint violations, and less intra-operative blood loss and intra-operative fluoroscopy time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00264-020-04825-1 | DOI Listing |
Brain Spine
December 2024
Department of Neurosurgery, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
Introduction: The role of low-pathogenic bacteria cultured from removed spinal implants is unclear and the efficacy of perioperative single-dose antibiotics against such bacteria remains underexplored.
Research Question: This study aims to investigate whether pedicle screw loosening is associated with pathogens and if the choice of perioperative antibiotics can prevent these bacteria.
Methods: A retrospective analysis was conducted on 93 patients with implants removed between 01/01/2018 and 03/31/2020.
Front Bioeng Biotechnol
December 2024
Department of Orthopaedics, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
Objective: In the current study, to demonstrate the advantages of oblique lateral interbody fusion (OLIF), we focused on the therapeutics for lumbar spinal tuberculosis with the comparison of three treatments, including anterior approach, posterior approach, and OLIF combined with posterior percutaneous pedicle screw fixation.
Methods: This study included patients with lumbar spinal tuberculosis from July 2015 to June 2018. We divided these patients into three groups: 35 patients underwent an anterior-only approach (Group A), 36 patients underwent a posterior-only approach (Group B), and 31 patients underwent OLIF combined with posterior percutaneous pedicle screw fixation (Group C).
J Orthop Surg Res
December 2024
Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, 510006, China.
Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.
Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.
Surg Radiol Anat
December 2024
Department of Anatomy, Digital Imaging and 3D Modelling Laboratory, Faculty of Medicine, Ege University, Bornova, 35100, Izmir, Turkey.
Purpose: The challenges of spinal surgery can be overcome by deeply understanding the anatomical and surgical complexities of the region through the use of model simulators. This study investigates the impact of digitally designed simulators, specifically lumbar spinal models with abnormal curvature, on preoperative planning and their effectiveness as training tools. The study addresses challenges in spine surgery, such as unique deformities, classification issues, and associated abdominal structure abnormalities.
View Article and Find Full Text PDFIndian J Orthop
January 2025
Department of Orthopaedic Surgery, Hillel Yaffe M.C., 3100 Hadera, Israel.
Objective: To present the clinical result of spinal fixation system made entirely of Carbon-Fiber-Reinforced (CFR)-Hybrid Polyaryl-Ether-Ether-Ketone (PEEK).
Summary Of Background Data: Fusion surgery has been used to treat chronic low back pain caused by degenerative disk disease (DDD). The traditional pedicle screw system made of titanium, though biocompatible, can lead to complications, such as stress shielding and implant failure.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!