A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Spectral sensitivity estimation of trichromatic camera based on orthogonal test and window filtering. | LitMetric

The three-channel spectral sensitivity of a trichromatic camera represents the characteristics of system color space. It is a mapping bridge from the spectral information of a scene to the response value of a camera. In this paper, we propose an estimation method for three-channel spectral sensitivity of a trichromatic camera. It includes calibration experiment by orthogonal test design and the data processing by window filtering. The calibration experiment was first designed by an orthogonal table of the 9-level and 3-factor. A rough estimation model of spectral sensitivity is established on the data pairs of the system input and output in calibration experiments. The data of rough estimation is then modulated by two window filters on frequency and spatial domain. The Luther-Ives condition and the smoothness condition are introduced to design the window, and help to achieve the optimal estimation of the system spectral sensitivity. Finally, the proposed method is verified by some comparison experiments. The results show that the estimated spectral sensitivity is basically consistent with the measured results of the monochromator experiments, the relative full-scale errors of the RGB three-channel is obviously lower than the Wiener filtering method and the Fourier band-limitedness method. The proposed method can estimate the spectral sensitivity of the trichromatic digital camera very well, which is of great significance for the colorimetric characterization and evaluation of imaging systems.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.401496DOI Listing

Publication Analysis

Top Keywords

spectral sensitivity
28
trichromatic camera
12
sensitivity trichromatic
12
spectral
8
orthogonal test
8
window filtering
8
three-channel spectral
8
calibration experiment
8
rough estimation
8
proposed method
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!