Characterization of Whole-Body Vibration (WBV) exposure is important for the development and evaluation of mitigation strategies for occupational WBV. However, barriers associated with cost and complexity limit widespread use of current gold-standard accelerometer (GSA) measurement systems. Small, simple, low cost Acceleration Measurement Unit (AMU) devices with built-in batteries and memory potentially allow for more efficient collection of WBV data, but the measurement accuracy of these devices need to be evaluated. Using known acceleration inputs generated by an accelerometer calibrator and field collected vibration profiles simulating real-world vibration exposures, the measurements of an AMU device and GSA system were compared. Analysis of accelerometer calibrator data showed no significant difference in weighted acceleration (A) measurements between the systems (mean difference -0.001 m/s, p = 0.95). In field collected vibration profile testing, differences in A measurements were small (0.06 m/s, 4.6%). These results suggest the AMU evaluated in this study may be acceptable for measuring occupational WBV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apergo.2020.103268DOI Listing

Publication Analysis

Top Keywords

measurement accuracy
8
low cost
8
acceleration measurement
8
measurement unit
8
gold-standard accelerometer
8
occupational wbv
8
accelerometer calibrator
8
field collected
8
collected vibration
8
vibration
5

Similar Publications

Postural stability measures as diagnostic tools for chronic ankle instability: a comprehensive assessment.

BMC Sports Sci Med Rehabil

January 2025

Department of Physiotherapy, School of Rehabilitation, Tehran University of Medical Science, Enghelab St, Pich-e-Shemiran, Tehran, Iran.

Background: Chronic ankle instability (CAI) is characterized by recurrent sprains and persistent symptoms, which impair postural control. This study evaluates the diagnostic utility of various linear and nonlinear postural stability measures in distinguishing individuals with CAI from healthy controls.

Methods: Postural stability was assessed in 24 participants (12 with CAI and 12 healthy controls) using a force platform under four conditions: hard surface with eyes open, hard surface with eyes closed, soft surface with eyes open, and soft surface with eyes closed.

View Article and Find Full Text PDF

Background: Creatinine-based estimated glomerular filtration rate (eGFR) equations are widely used in clinical practice but exhibit inherent limitations. On the other side, measuring GFR is time consuming and not available in routine clinical practice. We developed and validated machine learning models to assess the trustworthiness (i.

View Article and Find Full Text PDF

An applied noise model for scintillation-based CCD detectors in transmission electron microscopy.

Sci Rep

January 2025

Nanopatterning-Nanoanalysis-Photonic Materials Group, Department of Physics, Paderborn University, Warburgerstr. 100, 33098, Paderborn, Germany.

Measurements in general are limited in accuracy by the presence of noise. This also holds true for highly sophisticated scintillation-based CCD cameras, as they are used in medical applications, astronomy or transmission electron microscopy. Further, signals measured with pixelated detectors are convolved with the inherent detector point spread function.

View Article and Find Full Text PDF

3D scanner's potential as a novel tool for lymphedema measurement in mouse hindlimb models.

Sci Rep

January 2025

Department of Plastic and Reconstructive Surgery, Faculty of Medicine, Hokkaido University, Sapporo, Japan.

Lymphedema is characterized by persistent swelling due to impaired lymphatic function and presents significant challenges in both research and clinical settings. Traditional contact-based measurement techniques such as paw thickness and circumferential measurements using calipers or silk thread are useful but limited by observer variability and measurement accuracy. Non-contact methods, including various imaging techniques, offer improvements but often at higher cost and complexity.

View Article and Find Full Text PDF

Future Direction of Wound Care.

Nurs Clin North Am

March 2025

UC Davis Health System, 4860 Y Street, Sacramento, CA 95817, USA. Electronic address:

Chronic wounds are a common condition that affects a patient's quality of life and drives the cost of health care delivery high. Vigilant wound assessment and close monitoring using adequate and reliable methods and technology are vital to wound care management. Wound assessment, including visual evaluation of tissue and surrounding skin, and measurements are essential in developing an appropriate care plan.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!