Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2020.09.052 | DOI Listing |
Ultrasound Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:
Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Radiological and Hematological Sciences, Section of Radiology, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8 - 00168 Rome, Italy.
Background: Cardiac strangulation (CS) from epicardial pacing leads (EPLs) is a rare and potentially lethal mechanical complication associated with epicardial pacemaker (PM) implantation.
Case Summary: We report a case of a 44-year-old-female patient presenting with chest and left shoulder pain in the absence of reported trauma with history of congenital atrioventricular block treated with epicardial PM implantation during the childhood and subsequent transvenous reimplantation over the years. Troponin I resulted within normal values and ECG, transthoracic echocardiography and chest X-ray documented no acute cardiopulmonary findings.
Eur Heart J Imaging Methods Pract
January 2025
A.I. Virtanen Institute, University of Eastern Finland, Neulaniementie 2, 70210 Kuopio, Finland.
Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .
Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.
Herzschrittmacherther Elektrophysiol
January 2025
Klinik für Innere Medizin-Kardiologie, Diabetologie und Nephrologie, Evangelisches Klinikum Bethel, Universitätsklinikum OWL der Universität Bielefeld, Campus Bielefeld-Bethel, Burgsteig 13, 33617, Bielefeld, Germany.
Like children, adult patients with active or abandoned epicardial pacing leads are also at risk of developing life-threatening cardiac ischemia due to mechanical compression of the coronary arteries. As this complication is amenable to surgical removal, these patients require periodic evaluation for myocardial ischemia even if they are asymptomatic.
View Article and Find Full Text PDFQuant Imaging Med Surg
December 2024
Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Background: Segmented cine imaging using a balanced steady-state free precession sequence is the gold standard for accurately quantifying cardiac function and myocardial mass. However, this method suffers from inefficient K-space sampling, resulting in long scan times, and requires multiple breath holds that can be difficult for some patients. Real-time compressed sensing (CS) cine reduces image acquisition time through K-space undersampling and iterative reconstruction, enabling rapid magnetic resonance (MR) imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!