A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel method combining aptamer-AgNPs based microfluidic biochip with bright field imaging for detection of KPC-2-expressing bacteria. | LitMetric

A novel method combining aptamer-AgNPs based microfluidic biochip with bright field imaging for detection of KPC-2-expressing bacteria.

Anal Chim Acta

State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry Engineering, Nanjing University, No 163, Xianlin Avenue, Nanjing, 210023, PR China. Electronic address:

Published: October 2020

The β-lactam drugs resistance poses a serious threat to human health throughout the world. Klebsiella pneumoniae carbapenemase 2 (KPC-2) is a carbapenemase that produced in bacteria can hydrolyze carbapenems, which typically considered as the antibiotics of last resort. Therefore, there is an urgent need to quickly and accurately detect whether bacteria express KPC-2. In this paper, a PDMS/glass microfluidic biochip integrated with aptamer-modified AgNPs nano-biosensors was developed for rapid, simple and specific pathogenic bacteria detection, more importantly, the biochip was combined with bright field imaging, then the captured bacteria could be observed and counted directly without using extra chemical labeling. KPC-2-expressing Escherichia coli (KPC-2 E.coli) was used as the target bacterium with a detected limit of 10 CFU and capture efficiency exceeded 90%. This method is remarkably specific towards KPC-2 E.coli over other non-resistant bacteria, and pathogen assay only takes ∼1 h to complete in a ready-to-use microfluidic biochip. Furthermore, the effective capture and fast counting of microfluidic biochip system demonstrates its potential for the rapid detection of antibiotic-resistant bacteria.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2020.07.061DOI Listing

Publication Analysis

Top Keywords

microfluidic biochip
16
bright field
8
field imaging
8
kpc-2 ecoli
8
bacteria
7
biochip
5
novel method
4
method combining
4
combining aptamer-agnps
4
aptamer-agnps based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!