Background: Historically, anterior-posterior (AP) spread assessments were often used to determine the length that a distal cantilever could be extended off an implant-supported fixed full-arch prosthesis.

Types Of Studies Reviewed: The authors searched the literature for articles that used AP spread to calculate cantilever size to be constructed off implants bearing a fixed implant-supported full-arch rehabilitation.

Results: The data indicate that the relationship between AP spread and cantilever length is not linear and many influences (such as beam theory, cantilever size differences in the mandible versus maxilla, number and distribution of placed implants, prosthetic materials, and framework design) need to be considered when computing cantilever length with respect to fixed implant-supported prostheses.

Practical Implications: Recommendations using AP spread assessments to compute cantilever lengths have not been validated by means of prospective scientific evaluations. Therefore, AP spread evaluation is just one of many issues that need to be considered when determining distal cantilever length associated with a fixed full-arch implant-bearing prosthesis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.adaj.2020.06.016DOI Listing

Publication Analysis

Top Keywords

cantilever length
16
distal cantilever
12
fixed implant-supported
12
anterior-posterior spread
8
cantilever
8
implant-supported full-arch
8
spread assessments
8
fixed full-arch
8
cantilever size
8
spread
6

Similar Publications

Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories.

Rev Sci Instrum

January 2025

OzGrav-ANU, ARC Centre for Gravitational Astrophysics, College of Science, The Australian National University, Canberra ACT2601, Australia.

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10-16m/Hz at 1 kHz. This sensitivity is necessary for future tests of thermal noise models on cross sections of silicon suspension samples proposed for future gravitational-wave detectors. A volume of ∼36 l is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise.

View Article and Find Full Text PDF

Background: Determining the distal cantilever length in All-on-Four (All-on-4) implant-supported prostheses is a major factor in the long-term success of these prostheses. The difference in mechanical properties of materials used in the fabrication of these prostheses, such as polyether ether ketone (PEEK), may have an impact on the determination of the cantilever length that best distributes stress.

Aim: To study the distribution of stress in All-on-4 mandibular prostheses in the bone, implants, and framework according to difference cantilever length in PEEK prosthetic framework using three-dimensional finite element analysis.

View Article and Find Full Text PDF

Femtosecond Laser Introduced Cantilever Beam on Optical Fiber for Vibration Sensing.

Sensors (Basel)

November 2024

Hubei Key Laboratory of Optical Information and Pattern Recognition, Wuhan Institute of Technology, Wuhan 430205, China.

An all-fiber vibration sensor based on the Fabry-Perot interferometer (FPI) is proposed and experimentally evaluated in this study. The sensor is fabricated by introducing a Fabry-Perot cavity to the single-mode fiber using femtosecond laser ablation. The cavity and the tail act together as a cantilever beam, which can be used as a vibration receiver.

View Article and Find Full Text PDF

The geometry of implants plays a crucial role in the success of All-on-Four treatments for the lower jaw. This study builds upon prior research by evaluating the biomechanical performance of implant-supported prostheses in full-arch fixed dental restorations, specifically focusing on different implant lengths and connection types in cases of mild atrophic resorption of the mandible. Four groups were analyzed using finite element analysis (FEA): We utilized 13 or 18 mm posterior 17-degree tilting implants, each paired with two kinds of abutment connections.

View Article and Find Full Text PDF

Objective: The aim of the present study was to investigate the relation of the implant position to the implant crown and analyze the location and magnitude of bite force.

Materials And Methods: The dimensions of 49 posterior implant-supported restorations were recorded in terms of: 1. implant diameter, 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!