Objectives: To investigate the effect of pH control through the use of a citrate-buffered saline diluent pH 7 on the degradation rate of piperacillin/tazobactam solutions for infusion and to determine if an extended shelf-life of up to 13 days fridge 2°C-8°C plus 24 hours 'in-use' at 32°C in two elastomeric devices: FOLFusor LV10 (Baxter Healthcare, Thetford, UK) and Easypump II (B. Braun Medical Ltd, Sheffield, UK) can be achieved.

Methods: Testing was as per the latest National Health Service (NHS) Pharmaceutical Quality Assurance Committee Yellow Cover Document (YCD) requirements.A validated stability indicating high-performance liquid chromatography method was used for assessing the stability of the solutions of piperacillin/tazobactam at a combined concentration of 25 mg/mL and 90 mg/mL respectively. Solutions were tested in two batches in replicate (n=3) at five time points according to the requirements of the YCD.

Results: Piperacillin/tazobactam stability was significantly improved when 0.3% w/v citrate-buffered saline pH 7 was used as the diluent, compared with using 0.9% w/v saline as diluent. Greater than 95% of the zero-time concentration of both actives remained following storage at 2°C-8°C for up to 13 days plus 24 hours at 32°C in both devices. The data support extended storage of up to 13 days 2°C-8°C plus 24 hours at 32°C 'in-use' when using FOLFusor LV10 (Baxter) or Easypump II (B. Braun) pump devices.

Conclusions: The enhanced stability complies with UK national standards as stated in the YCD for stability testing of aseptically produced small molecules and supports the storage of piperacillin/tazobactam for up to 13 days 2°C-8°C plus 24 hours at 32°C 'in-use' within two elastomeric pump devices. The extended shelf-life provides a significant advantage over the stability of piperacillin/tazobactam solutions for infusion when reconstituted and diluted in 0.9% w/v saline as diluent. The data open up the possibility of a continuous infusion of piperacillin/tazobactam delivered by elastomeric pump devices over 24 hours in an outpatient parenteral antimicrobial therapy setting.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9251159PMC
http://dx.doi.org/10.1136/ejhpharm-2020-002340DOI Listing

Publication Analysis

Top Keywords

saline diluent
16
2°c-8°c hours
12
hours 32°c
12
continuous infusion
8
elastomeric devices
8
outpatient parenteral
8
parenteral antimicrobial
8
yellow cover
8
cover document
8
citrate-buffered saline
8

Similar Publications

Stability of diluted chlorhexidine for skin testing in drug allergy evaluations.

J Allergy Clin Immunol Glob

February 2025

Division of Allergy, Asthma and Clinical Immunology, Mayo Clinic, Scottsdale, Ariz.

Background: Chlorhexidine gluconate (CHX), a common cause of perioperative anaphylaxis, is frequently used for skin testing in allergy evaluations. Although CHX's maximal nonirritating concentrations are known, the stability of its dilutions for skin testing remains unexplored, particularly when sterile water for injection (SWFI) or normal saline (NS) are used as diluents.

Objective: Our aim was to evaluate the stability and precipitation of CHX when diluted with SWFI or NS for drug allergy skin testing.

View Article and Find Full Text PDF

Background: At the regional transfusion service in the Region of Southern Denmark, serological investigations are primarily carried out using column agglutination techniques. This case study examines an unusual instance of reagent interference in pretransfusion testing using column agglutination at the Hospital of Southern Denmark, Aabenraa.

Case Presentation: A 72-year-old male patient presented for pretransfusion testing prior to hernia surgery.

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Objectives: To observe the effect of electroacupuncture (EA) preconditioning at "Quchi" (LI11) and "Xuehai" (SP10) in prevention of urticaria.

Methods: Twenty-four male SD rats were randomly divided into control, model and preconditioning of EA (Pre-EA) groups (8 rats/group). The urticaria model was established by intradermal injection of dilute allogeneic antioalbumin serum at the spots of the bilateral symmetry of the spine on the back, and followed by tail venous injection of mixture solution of egg albumin diluent, plus 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!