The Bidirectional Glenn (BDG) or cavopulmonary connection is typically undertaken to volume unload the single ventricle in an effort to preserve ventricular and atrioventricular valve function. The geometry of this surgical palliation has been shown to influence the fluid energy loss as well as the distribution of flow that enters through the superior vena cava. In-vitro and in-silico studies to date have been performed on rigid wall models, while this investigation looks at the impact of flexible thin walled models versus rigid walls. Rigid and compliant models of two patient-specific Glenn geometries were fabricated and tested under various flow conditions, within a biosimulator capable of replicating patient specific flow conditions. It was found that the compliant models exhibit greater levels of energy loss compared to the rigid models. Along with these findings greater levels of turbulence was found in both compliant models compared to their rigid counterparts under ultrasound examinations. This shows that vessel compliance has a significant impact on the hemodynamics within hypoplastic left heart syndrome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2020.07.012 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!