A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of metal uptake in single organisms, Corophium volutator, via complementary electrothermal vaporization/inductively coupled plasma mass spectrometry and laser ablation/inductively coupled plasma mass spectrometry. | LitMetric

Rationale: (Eco-)toxicological effects are mostly derived empirically and are not correlated with metal uptake. Furthermore, if the metal content is determined, mostly bulk analysis of the whole organism population is conducted; thus, biological variability is completely disregarded, and this may lead to misleading results. To overcome this issue, we compared two different solid sampling techniques for the analysis of single organisms.

Methods: In this study, complementary electrothermal vaporization/inductively coupled plasma mass spectrometry (ETV/ICP-MS) ⇔ laser ablation/inductively coupled plasma mass spectrometry (LA/ICP-MS)-based methods for the analysis of individual organisms were developed and the results obtained were compared with the concentrations obtained after digestion and measured using ICP-MS. For this purpose, a common (eco-)toxicological test organism, the mud shrimp Corophium volutator, was selected. As proof-of-concept application, these organisms were incubated with environmentally relevant metals from galvanic anodes, which are often used for protection against metal corrosion in, for example, offshore wind farms.

Results: The bulk analysis revealed that large quantities of the incubated elements were detectable. Using the ETV/ICP-MS method, we could identify a high biovariability within the population of organisms tested. Using the LA/ICP-MS method, it could be determined that the large quantities of the elements detected were due to adsorption of the metals and not due to uptake, which correlates well with the absence of (eco-)toxicological effects.

Conclusions: The results obtained imply the efficiency of complementary methods to explain the absence or presence of (eco-)toxicological effects. In particular, methods that allow for single-organism analysis or provide even a spatial resolution support the interpretation of ecotoxicological findings.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.8953DOI Listing

Publication Analysis

Top Keywords

coupled plasma
16
plasma mass
16
mass spectrometry
16
metal uptake
8
corophium volutator
8
complementary electrothermal
8
electrothermal vaporization/inductively
8
vaporization/inductively coupled
8
laser ablation/inductively
8
ablation/inductively coupled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!