Goal: This paper presents an algorithm for accurately estimating pelvis, thigh, and shank kinematics during walking using only three wearable inertial sensors.
Methods: The algorithm makes novel use of a constrained Kalman filter (CKF). The algorithm iterates through the prediction (kinematic equation), measurement (pelvis position pseudo-measurements, zero velocity update, flat-floor assumption, and covariance limiter), and constraint update (formulation of hinged knee joints and ball-and-socket hip joints).
Results: Evaluation of the algorithm using an optical motion capture-based sensor-to-segment calibration on nine participants (7 men and 2 women, weight [Formula: see text] kg, height [Formula: see text] m, age [Formula: see text] years old), with no known gait or lower body biomechanical abnormalities, who walked within a [Formula: see text] m capture area shows that it can track motion relative to the mid-pelvis origin with mean position and orientation (no bias) root-mean-square error (RMSE) of [Formula: see text] cm and [Formula: see text], respectively. The sagittal knee and hip joint angle RMSEs (no bias) were [Formula: see text] and [Formula: see text], respectively, while the corresponding correlation coefficient (CC) values were [Formula: see text] and [Formula: see text].
Conclusion: The CKF-based algorithm was able to track the 3D pose of the pelvis, thigh, and shanks using only three inertial sensors worn on the pelvis and shanks.
Significance: Due to the Kalman-filter-based algorithm's low computation cost and the relative convenience of using only three wearable sensors, gait parameters can be computed in real-time and remotely for long-term gait monitoring. Furthermore, the system can be used to inform real-time gait assistive devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TBME.2020.3026464 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!