A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Comparative Assessment of the Nova Stat Profile Prime Plus® Critical Care Analyzer. | LitMetric

Background: Point-of-care testing (POCT) plays an integral role in the management of acutely ill patients presenting to the emergency department (ED). Due to its rapid turnaround time, POCT has been shown to improve ED workflow, reduce unnecessary admissions and lessen the burden on ED staff. The aim of the study was to compare the accuracy, precision and linearity of the Nova Stat Profile Prime Plus (Nova Biomedical, Waltham, MA, USA) to the Radiometer ABL800 FLEX (Radiometer South Africa Pty Ltd, Gauteng) and the Abbott i-stat Chem8+ (Abbott, Princeton, NJ, USA) POCT analyzers.

Methods: A convenience sample of 150 discarded whole blood specimens was obtained and analyzed. Paired test measurements were conducted for method comparison. Accuracy was measured by pairing individual results from the Nova Stat Profile Prime Plus with either the Radiometer ABL800 FLEX or the Abbot i-stat Chem8+ analyzers by calculating the differences.

Results: The with-in run percentage coefficient of variation (%CV) was below 2.4% for pH, carboxyhemoglobin (COHb), deoxyhemoglobin (HHb), total hemoglobin (tHb), total bilirubin (tBil), sodium (Na), potassium (K), chloride (Cl), ionized calcium (iCa), urea, glucose and lactate, and was below 5.1% for all other analytes. The day-to-day %CV was below 1.6% for pH, COHb, HHb, tHb, tBil, Na, K, Cl, iCa, urea, glucose and lactate, and below 6.10% for all other analytes. The correlation coefficient (r) was 0.351 and ranged from 0.897 to 0.998 for all analytes. The mean bias was minimal for all analytes.

Conclusion: There was a good correlation between the Nova Stat Profile Prime Plus and the Radiometer ABL800 FLEX/Abbott i-STAT Chem8+ POCT analyzers. The Stat Profile Prime Plus exhibited good precision both within-run and day-to-day.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7505621PMC
http://dx.doi.org/10.7759/cureus.9932DOI Listing

Publication Analysis

Top Keywords

stat profile
20
profile prime
20
nova stat
16
radiometer abl800
12
prime radiometer
8
i-stat chem8+
8
ica urea
8
urea glucose
8
glucose lactate
8
stat
5